Maintenance
FREQUENCY
PERSONNEL
At the end of
Operator
every shift
of work and
before the daily
use
Troubleshooting
TYPE
Net voltage lacking
Functioning
intervention
MODALITY
PERIODS OF LONG INACTIVITY
During long inactive periods pass over all steel surfaces (especially if
stainless) with clothes soaked in Vaseline oil to spread a protective veil.
PRODUCTS NOT TO USE
•
Compressed air with jets towards the zones where food comes in
contact and in the general direction of the machine.
•
Vapor equipment, detergent that contains CLORO (also if diluted)
or its compounds such as: bleach, muriatic acid, marble cleaning,
general decalcifying, products to clear the drain, etc. They can
attack steel, staining and oxidizing is unavoidable. The described
products can oxidize and corrode steel.
•
Steel wool, brushes or abrasive discs produced with other metals or
alloys or tools that have previously cleaned other metals or alloys.
•
Detergents in abrasive dust.
•
Fuel, solvents or flammable and/or corrosive fluids.
•
Substances used to clean silver.
POTENTIAL
MODALITY AND COMPARISONS
CAUSES
General black out.
Contact the electric distributor.
Fuses or magneto
After having eliminated the causes that have caused
thermals intervention
intervention in the protection device, restore it. If the problem
place upstream of the
persists, contact an electrician.
machine feeding line.
Protection device
Contact an electrician. After having eliminated the causes
intervention inside
of the intervention, restore it. In case of fuses intervention,
the machine.
change them with types of the same model, calibration and
intervention curve.
Grater handle lifted.
The machine can be restarted by lowering the handle and
closing the mouth of the machine.
Cause(s) not
Direction contact Omcan.
identifiable.
14
Need help?
Do you have a question about the GR-IT-0373 and is the answer not in the manual?