Page 1
Operation Web interface The Internet portal for easy and secure access to your system data – www.vbus.net Thank you for buying this RESOL product. Manual Please read this manual carefully to get the best performance from this unit. www.resol.com Please keep this manual carefully.
Page 2
Proper usage Signal words describe the danger that may occur, when it is not avoided. The RESOL DL3 Datalogger is connected to RESOL controllers via the VBus ® • WARNING means that injury, possibly life-threatening injury, can occur. interface. It enables logging of system data and parameterisation of a solar thermal system.
Contents Overview ..................... 4 Basic configuration ................18 Finding the DL3 Datalogger by means of the DeviceDiscoveryTool ... 19 Included ....................5 Changing the web interface language ..............19 Installation ..................5 Changing the live data display language .............. 19 Wall mounting ......................6 Changing the user password .................
Overview The DL3 Datalogger is used for logging data of up to 6 RESOL controllers and Technical data permits the visualisation via www.VBus.net and the parameterisation via RPT. Get Housing: plastic, PC-ABS and PMMA a comprehensive overview of all controllers connected with the large full graphic Protection type: IP 20 / EN 60529 display, all important settings are directly adjustable on the DL3.
Initial installation must be effected by the system installer or qualifi ed personnel named by the system installer. If one of the items mentioned below is missing or defective, please contact your distributor: DL3 Datalogger Mains adapter Interchangeable mains adapter plugs (EURO, UK, USA, AUS) VBus cable ...
Î Hang the housing from the upper fastening point and mark the lower fastening Î Connect the mains adapter / to the DL3 and to a mains socket. points (centres 180 mm) Î For a direct connection to a router or a PC, connect the Datalogger to a Î...
LAN connection Colour Permanent Flashing The DL3 Datalogger can be connected to a computer or a router by using a net- Green The device is ready for operati- Do not remove the SD card! Data work cable (CAT5e, RJ45).
• Button : Scrolling downwards Display During normal operation, the DL3 Datalogger indicates the status display (see fig. Selecting options / menu points and adjusting values page 8). buttons and can be used to switch between the displays.
Page 9
Each sensor has its own display. The data of the inputs CL and S1 to S3 are displayed If the DL3 has not been assigned with an IP address, none of the symbols are indi- each in their own display.
Configuration Î Adjust the hours by pressing buttons and , and confirm with button . Î Adjust the minutes by pressing buttons and , and confirm with button . In the Configuration menu, different adjustments can be made. Î...
Page 11
In order to set back the heat quantity to zero, a reset can be run: Sensor offset Î Select the menu item Reset by pressing buttons and , and confirm with In order to adjust an offset for the sensor inputs S1 … S3, proceed as follows: button ✓.
Page 12
The menu item Recover IP can be used to automatically retrieve a new IP ad- 4.5.7 Network dress for the DL3 in the case that the previous one is lost. In order to adjust the automatic IP address configuration, proceed as follows: In the Network submenu, the following adjustments can be made: Î...
The menu item Reset can be used to erase all logged data from the internal memory of the DL3 Datalogger and to reset all adjustments made in the DL3 back The DL3 is equipped with a USB interface to which the USB adapter cable can be to their factory settings.
--Auto configuration Yes, No 4.10 VBus connection ® --Add. The DL3 Datalogger is connected to one or several RESOL controllers via VBus --Mask ® cables. The connection terminals are located inside the housing of the DL3 Data- --Recover IP Yes, No logger.
Î Activate VBus.net in the DL3. Web interface Î Note down the alphanumeric 8-10-digit code (Access Token) indicated on the The web interface is integrated in the DL3 Datalogger and can be run on an In- display of the DL3. ternet browser.
Menu The menu column with all main menus and their corresponding submenus are The menu bar at the top of the web interface contains the menu items Home, indicated on the left-hand side of the web interface. Live (see below) and Login. Note The menu structure may change in later firmware versions.
Downloading a customised view of the live data Displaying data in a tabular overview Resetting the live data display adjustments In this menu, a selection can be made whether to display all live data, internal DL3 data or data of a controller connected. State...
Î Change the user password Displaying data communication Î Change the device name In order to display statistics about the data exchange between the DL3 Datalogger Î Change the time configuration and the controllers connected, proceed as follows: Î Configure the automatic firmware update configuration Î...
Finding the DL3 Datalogger by means of the DeviceDiscovery- Changing the web interface language Tool The web interface can be run in different languages. The DeviceDiscoveryTool is a software that displays Dataloggers that are con- Î Click one of the small flags on the right-hand side of the Home screen, accord- nected directly or via the local network.
DL3 Datalogger and the NTP server. See chap. 10 Firmware update with SD card on page 28. • Manual: The user manually assigns date and time information to the DL3 Data- logger. In order to configure firmware updates, proceed as follows: Î...
Assigning a static router address In order to access the router and the DL3 connected over the Internet, a static The remote access password is required whenever a controller connected to the address has to be assigned to the router.
Page 22
Using a static Internet IP address DynDNS Schematic representation: Remote access to the DL3, router with static Internet IP address. Schematic representation: Remote access to the DL3, router with DynDNS address. It is possible to apply for a static Internet IP address at an Internet Service Provider Note (ISP).
In order to carry out port routing in the router, proceed as follows: Î Connect the DL3 Datalogger to the LAN network. Î Assign a static LAN IP address to the DL3 Datalogger using the configuration Î Connect the devices to the DL3 by means of the VBus ®...
Page 24
Note BACnet uses port 0xBAC0 (47808). Note Do not change the allocation of the VBus ® connections after BACnet ac- cess has been activated. BACnet retains the previous configuration. If the allocation is changed, the device has to be reset to its factory set- tings (see page 13).
Î In order to get back to the BACnet access tab, click on back. est data will be overwritten. Î In order to download an EDE file for the current DL3 BACnet configuration, • Linear logging: When the memory capacity is fully used, data logging stops.
See chap. 9.3 Log interval configuration on page 25. Î Click Save configuration. The message Configuration saved successfully! appears. Uploading a system drawing In order to upload a system drawing into the web interface of the DL3 Datalogger, Data display configuration proceed as follows: Î Start the RESOL ServiceCenter software.
The Export designer document to DL3 window opens. Advanced customization of the data display Î Enter the IP address of the DL3 Datalogger into the DL3 host name field. The user interface of the data display can be adapted to specific requirements by Î...
Î Copy the contents of the SDCARD folder onto the first level of the SD card. not enable public access to the Erase data menu! There should then be a folder structure called RESOL/DL3 on the SD card, con- taining the firmware file.
Data export over web interface Note There are 2 different ways to export logged data from the DL3 Datalogger: The internal processor of the DL3 Datalogger needs up to 30 minutes to 1. Export logged data onto an SD memory card. The data are stored as a VBus ®...
SSH configuration Eliminating errors The SSH configuration can be used for accessing the operating system of the DL3 Problems with the direct connection to a gigabit network device Datalogger. Problem Solution Damage through incorrect configuration! ATTENTION! When a device is connected Note The SSH configuration requires detailed knowledge in the area of...
Page 31
In order to eliminate the error, the current Java Î In the Settings menu, select the Control software has to be installed from http://java.com. panel. Î Check if an IP address is assigned to the DL3 Î Double-click the Internet Options symbol. Datalogger. Î Click the Connections tab.
Open Source applications and libraries can be ordered. under Linux or Mac OSX. Please send your order to: • Data are separated by a semicolon. RESOL – Elektronische Regelungen GmbH Excel • XLS file, optimised for processing in a spread- Heiskampstraße 10 sheet program compatible with MS Excel.
16.2 Unit conversion table Accessories Unit MBTU MMBTU 1 Wh 3.412128 0.003412 0.000003 1KWh 3412.128 3.412128 0.003412 Temperature sensors 1MWh 3412128 3412.128 3.412128 The product range includes high-precision platinum temperature sensors, fl atscrew sensors, outdoor temperature sensors, indoor temperature sensors, cylindrical Unit g CO2_OIL kg CO2_OIL...
Page 36
- they only represent This mounting- and operation manual including all parts is copyrighted. Another use outside the copyright requires the approval of RESOL – Elektronische Rege- some examples. They can only be used at your own risk. No liability is assumed for lungen GmbH.
Need help?
Do you have a question about the DL3 and is the answer not in the manual?
Questions and answers