Maintenance Tasks: Qualified Service Technician - Monessen Hearth AVFL60NIP Owner's Manual

Hide thumbs Also See for AVFL60NIP:
Table of Contents

Advertisement

C. Maintenance Tasks: Qualified Service
Technician
The following tasks must be performed by a qualified ser-
vice technician.
Pilot
Frequency: Annually
By: Qualified Service Technician
Tools needed: Small soft brush, pipe cleaner
• Inspect and remove dust, spider webs and lint
• Gently run pipe cleaner through air intake port
Firebox
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace fireplace if firebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.
Monessen • AVFL60 Owner's Manual • 4605-900 Rev. A • 5/17
Bulb Installation
Turn OFF the main power supply before perform-
ing any service work on the unit, including install-
ing or replacing light bulbs.
Figure 5.1 Top Light Position
Dome Light Bulb Replacement
1. Remove three screws holding the left light cover in
place.
See Figure 5.2.
2. Insert (1) bulb provided into socket
3. Replace top light cover with three screws
4. Repeat on right side light cover
Figure 5.2 Top Light Screws
TOP LIGHT LOCATION
Light cover
screws
23