About ON Mode
• All functions can be accessed when the remote control
is in the ON mode.
• Only active functions will be displayed when the remote
control is in the ON mode.
About OFF Mode
Only the following functions can be accessed in the OFF
mode:
• AUX1
• AUX2
Only active functions will be displayed when the remote
control is in the OFF mode.
Turning On the Fireplace
• Press the POWER button to turn the fireplace ON. The
fireplace will first ignite the pilot. Once the pilot flame is
established the main burner will be lit.
NOTICE: Whenever the fireplace is cycled from OFF to
ON, the main burner will light on high for 10 seconds before
returning to the previous user setting.

Adjusting Flame Height

• Press the MENU button to activate the menu.
• Using the UP and DOWN arrows highlight the FLAME
icon and press SELECT.
• Use the UP and DOWN arrows to adjust the FLAME
HEIGHT, then press SELECT. The FLAME HEIGHT
can be adjusted to 5 different settings.
NOTICE: FLAME HEIGHT will not be adjustable for first
ten seconds when fireplace is turned on.
NOTICE: The system will remember the previous FLAME
HEIGHT setting and will automatically adjust after 10
seconds.
NOTICE: Some models use fixed valves, which cannot
be adjusted.
AUX1 Function (Top Dome Lighting)
• Press the MENU button to activate the menu.
• Using the UP and DOWN arrows highlight the AUX1 icon
and press SELECT.
• Use the UP and DOWN arrows to adjust the AUX1 output,
then press SELECT. The AUX1 function can be adjusted
to 4 different settings: HI, MED, LOW and OFF.
18
Monessen • AVFL60 Owner's Manual • 4605-900 Rev. A • 5/17
Adjusting Thermostat
• Press the MENU button to activate the menu.
• Using the UP and DOWN arrows highlight the THERMO
icon and press SELECT.
• Use the UP and DOWN arrows to turn the THERMO ON
or OFF, then press SELECT (the SET TEMP will start
blinking). Using the UP and DOWN arrows select the
desired temperature and press SELECT.
NOTICE: If the THERMO function is on, the SET TEMP
can be adjusted at any time by pressing the UP and DOWN
arrows.
NOTICE: As the ROOM TEMP (RT) approaches SET
TEMP (ST), the remote system will automatically adjust
the flame height. If the RT rises above ST, the fireplace
will shut down the main burner. After this, the fireplace will
turn back on after the RT drops below the ST.
NOTICE: The system requires a two degree Fahrenheit
or higher temperature difference between RT and ST for
the fireplace to turn on.
NOTICE: The system will remember the previous TEM-
PERATURE setting when THERMOSTAT mode is cycled
ON or OFF.
NOTICE: If your installation includes an optional wired ON/
OFF wall switch, it should be in the OFF position when
using the RC300 in thermostat mode.
Adjusting Timer
• Press the MENU button to activate the menu.
• Using the UP and DOWN arrows highlight the TIMER
icon and press SELECT.
• Use the UP and DOWN arrows to turn the TIMER ON
or OFF, then press SELECT. Using the UP and DOWN
arrows select the desired set time and press SELECT.
Timer operates in increments of 15, 30, 45, 60, 90, 120
and 180 minutes.
Setting the Child Lock
• Press and hold the MENU and UP arrow buttons simul-
taneously for 4 seconds to enable or disable the child
lock feature.
NOTICE: No functions will be usable until child lock feature
is disabled.