Fault
Programs cannot be
entered
Manual opening via the
man. On / Off-key is not
possible
Watering program is not
being undertaken
(no watering)
Possible Cause
Rechargeable battery is flat.
Temperature on the display
is higher than 60 °C.
The current time and the day
of the week were not entered
completely.
Manual watering period is set
0 0 : : 0 0 0 0
to
.
Tap turned off.
Watering program has not
been entered completely.
Programs deactivated
(Prog. Off).
Remedy
v Place Water Computer
in the sun for 1 - 2 days
or charge the battery with
a charger for 9 V block /
NH 22 rechargeable
batteries.
Display appears after
temperature has dropped.
v Check function by operating
manually.
v Enter time and day of week
(see 5. Programming).
v Set manual watering period
to a figure greater than
0 0 : : 0 0 0 0
(see 5. Programming).
v Turn tap on.
v Read off watering program
and modify if necessary.
v Activate program
(% Run-Time).