HIGH-LEVEL INPUT: Connections should be made to the same binding post on main amplifier as the main
speakers. Red to amplifier main right speaker red terminal, yellow to amplifier main left speaker red terminal
and black to amplifier main speaker black terminal, right or left but not both. Plug the Neutrik Speakon plug
into the HIGH-LEVEL Speakon socket.
Note: This connection does not draw power from the power amplifier and, yes, your REL is a powered
sub bass system. However, by deriving its signal from the main power amplifier, better sound quality
is achieved.
.1/LFE INPUT: This requires a phono-to-phono cable and is a dedicated true .1 channel. This circuit therefore
eliminates the normal Natural RollOff™ Crossover and passes the .1 LOW-LEVEL signal through with only the
required 120Hz fourth-order filter.
These connections can be made on the SerieT/i through the REL Arrow™ transmitter, or direct to the back
panel of the cabinet. In the case of connecting directly, only the subwoofer cabinet will need power. Using
input connections to both the REL Arrow™ Wireless Transmitter and direct to the SerieT/i back panel are
not permitted.