Accessories for Dual Air / Water Heat Pumps Operating Manual Hydraulic Module HMD 1/E HMD 1/RE 83053600eUK – Translation into English of the original German operating manual...
Please read first Symbols This operating manual provides important information The following symbols are used in the operating manual. on the handling of the unit. It is an integral part of the They have the following meaning: product and must be stored so that it is accessible in the immediate vicinity of the unit.
Intended use Safety The hydraulic module is a functionally-necessary The unit is safe to operate for its intended use. The accessory for dual air/water heat pumps intended for construction and design of the unit conform to current outdoor installation. Taking into account the limits of state of the art standards, all relevant DIN/VDE application, the unit can be used in combination with an regulations and all relevant safety regulations.
Customer service Operation For technical information please contact a qualified Your decision to purchase a heat pump or a heat technician or the manufacturer’s local partner. pump system is a long-term contribution to protecting the environment through low emissions and reduced primary energy use.
Maintenance of the unit Malfunctions The components of the heating circuit and the heat In the event of a fault, you can read out the cause of the source (valves, expansion vessels, circulating pumps, fault from the diagnostic program of the heating and heat filters, dirt traps) should be inspected and cleaned as pump regulator.
COMPONENTS OF THE UNIT FOUR VERSIONS OF THE HYDRAULIC MODULE ARE AVAILABLE: HMD 1/E HMD 1/RE COMPONENTS OF THE UNIT Safety assembly for heating circuit (insulated) Air separator Continuous flow heater 6kW Flow monitor Expansion vessel 12l Circulating pump for heating circuit (Energy efficient circulating pump)
The installation area must be frost-free and dry. It must fulfil the relevant local regulations. Possible installation situation, Dimensional drawing and installation plan for Example: HMD 1/E with row tank respective model. 1 Hydraulic module 2 Buffer storage tank 3 Domestic hot water tank...
Page 10
The board material must be dimensioned with sufficient thickness to ensure secure fixing. Appropriate fixing material must be provided on site for other types of wall constructions. Example: HMD 1/E: ATTENTION 1 Recessed grips Leaving a gap between the unit and the wall...
INSTALLATION / HYDRAULIC CONNECTION TO HEATING EXPANSION VESSELS CIRCUIT The expansion vessel for the heating circuit is integrated. The connections for the heating circuit are located on Always check whether the size of the expansion vessel is the underside of the unit. large enough for the system.
(if required by the latter)! Example: HMD 1/E 1 Terminal strip, power supply cable NOTE. - Heat pump All live wires must be stripped before they are - Heating element...
Use cable ties and heat transfer compound to fix the NOTE. return flow sensor (3) to the return flow (heat carrying The control element of the heat and heat pump pipe) to the heat pump (4). regulator can be connected with a computer or network using a network cable designed for such Hydraulic connections documents purposes, therefore allowing the heating and...
4 Return flow, domestic hot water 5 Drain Example: HMD 1/E with row tank-connection “Switching valve” operating manual Connect hose to the filling and draining tap and lay Dismantle the motor of the 3-way valve for the it to a drain…...
Set the overflow valve Open shut-off valves in the hydraulic module on the heat pump side. Close shut-off valves of the module on the heating circuit side. Close shut-off valves on REMARQUE site on the heating pump side: The activities in this section are only necessary for in-line tank integration.
If this is the case, push in the button. HMD 1/E 1 Safety temperature button on electric heating element Example: HMD 1/E 2 Reset knob NOTE. HMD 1/RE: A connection to a computer or a network can...
Dismantling DANGER! Risk of fatal injury due to electric shock! Electrical connections may be installed only by qualified electricians. Before opening the unit, disconnect the system from the power supply and prevent it from being switched back on! WARNING! Only qualified heating or cooling system technicians are allowed to remove the unit from the system.
Dimensional drawings HMD 1/E Legende: D819396- We reserve the right to modify technical specifications without prior notice. All dimensions in mm. Front view Side view from right The hydraulic module is installed in the heating flow! Item Designation Das Hydraulikmodul wird im Heizungsvorlauf Dim.
Dimensional drawings HMD 1/RE Legende: D819412a We reserve the right to modify technical specifications without prior notice. All dimensions in mm. Front view Side view from right Legende: D819412a Das Hydraulikmodul wird im Heizungsvorlauf Technische Änderungen vorbehalten. The hydraulic module is installed in the heating flow! installiert! Alle Maße in mm.
Installation plan HMD 1/E >1350 >200 >600 Legende: 819398- Technische Änderungen vorbehalten. Legende: 819398- Alle Maße in mm. All dimensions in mm. OKF Oberkante Fertigfussboden Freiraum für Servicezwecke Freiraum für wandhängenden Top surface finished floor Pufferspeicher 50L (Zubehör) möglich Free space for service purposes...
Installation plan HMD 1/RE >1350 >200 >600 Legende: 819413a Technische Änderungen vorbehalten. Legende: 819413a Alle Maße in mm. All dimensions in mm. OKF Oberkante Fertigfussboden Freiraum für Servicezwecke Top surface finished floor Free space for service purposes ÄM 045/2012 PEP 001/2012 Zust.
HMD 1/E Row tank Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
Separate buffer tank HMD 1/E Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
HMD 1/RE Unit variant R (cooling) Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
Terminal diagram LWD... / HMD 1/E, HMD 1/RE 3~N/PE/400V/50Hz 3~N/PE/400V/50Hz 3~N/PE/400V/50Hz ZW2/SST 1~N/PE/230V/50Hz Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
HMD 1/E Circuit diagram 1/2 Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
Page 32
Circuit diagram 2/2 HMD 1/E Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
HMD 1/RE Circuit diagram 1/2 Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
Page 34
Circuit diagram 2/2 HMD 1/RE Subject to change without notice | 83053600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH...
EC Declaration of Conformity in accordance with the EC Machinery Directive 2006/42/EC, Annex II A The undersigned confirms that the following designated device(s) as designed and marketed by us fulfill the standardized EC directives, the EC safety standards and the product-specific EC standards. In the event of modification of the device(s) without our approval, this declaration shall become invalid.