Fujitsu PRIMERGY RX1330 M3 Operating Manual page 60

Hide thumbs Also See for PRIMERGY RX1330 M3:
Table of Contents

Advertisement

Starting up and operation
Pos. Label
2
[CSS]
3
4
5
60
Indicator
Status
off
CSS
orange
indicator
on
orange
flashing
off
orange
Global
on
Error
indicator,
see also
"iRMC-
related
orange
status
flashing
signals" on
page 61
HDD/SSD
green
activity
flashing
indicator
off
green on
Power-on
indicator
green
flashing
slowly
Operating Manual
Description
No critical event detected (CSS
component).
Prefailure event detected (CSS
component).
CSS component failure detected.
No critical event detected (non
CSS component).
Prefailure event detected (non
CSS component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
range
– Defective sensor
– CPU error
– Error detected by server
management software
Data access in progress.
– The server is switched off.
– The server has been switched
on but Power Cycle Delay
settings delay it from turning
on for a specified time.
– The server is switched on and
operating normally.
iRMC S4 is not ready.
RX1330 M3

Advertisement

Table of Contents
loading

Table of Contents