1. If no protections have occurred, "No Protect" is
displayed
2. if last protection was ASO, "ASO" is displayed.
Cause: A short circuit occurred between the speaker terminals, or speakers with an impedance outside the rating were connected. If the power is turned on
during this abnormality, protection is activated after around 5 seconds and the power is turned off.
3. If the last protection was DC, "DC" is displayed.
Cause: DC output of the power amplifier is abnormal.
If the power is turned on during this abnormality, protection is activated after around 5 seconds and the power is turned off.
4. If the last protection was THERMAL A or B "THERMAL A
or B is displayed.
Cause: Abnormal heat sink temperature.
If the power is turned on during this abnormality, protection is activated after around 5 seconds and the power is turned off.
Caution: These protections may also be activated due to causes such as disconnection of connectors or operations around the
microcomputer.
After viewing the above protection history, press the button "STATUS" to return to the normal display.