Excell EX2005 User Manual page 75

Table of Contents

Advertisement

EXCELL PRECISION CO., LTD
Function code 06: Modbus (41026): write batch finish delay time write
Name
Input
ID Address
01
Function
06
code
04
Register's
address
02
00
Setting
value
07
xx
CRC
xx
Function code 01: Modbus (00000~00001): read current scale status
Name
Input
ID Address
01
Function
01
code
00
Register's
address
00
00
Setting
value
02
BD
CRC
CB
04011210
Description
Machine ID
Batch Finish delay
time address
1026
= 04 02
(10)
(HEX)
Input value 7s
is 0007
(HEX)
Description
Machine ID
Starting Address
Read 2 status (2 Bit)
00000~00001
Name
Output
ID Address
01
Function
06
code
04
Register's
address
02
00
Setting
value
07
xx
CRC
xx
Name
Output
ID Address
01
Function
01
code
Bit
02
D0
CRC
49
73
Description
Machine ID
Batch Finish delay
time address
1026
= 04 02
(10)
(HEX)
Input value 7s
is 0007
(HEX)
Description
Machine ID
Read 2 Bit data:
2=10
, 00001 = 1
(2)
(return to zero) or 0
(non return to zero),
00000 = 0 (stable) or
1 (unstable)
ZSME400000003

Advertisement

Table of Contents
loading

Table of Contents