Appendix 4 MODBUS Data Address Table II

(For Hitech and Pro-face Human Machine Interface)
Data Register
Function Code 03 (Read)
Modbus
SCALE
40001 ~ 40002
As display value
40003 ~ 40004
Gross weight
40005 ~ 40006
Net weight
40007 ~ 40008
Tare weight
Gross weight
40009 ~ 40010
hold value
Net weight
40011 ~ 40012
hold value
Weight final
40013 ~ 40014
value
40015 ~ 40016
Unit weight
Percentage
40017 ~ 40018
value
40019 ~ 40020
Totalised value
40021 ~ 40022
Totalised times
Totalised times
40023 ~ 40024
of HI value
Totalised times
40025 ~ 40026
of Lo value
Totalised times
40027 ~ 40028
of OK value
Function Code 06 and 16 (Write)
41001 ~ 41002
Pre-tare value
41003 ~ 41004 Zero Band value
41005 ~ 41006
Target value
41007 ~ 41008
SP1 value
41009 ~ 41010
SP2 value
41011 ~ 41012
SP3 value
41013 ~ 41014
LO_LO value
41015 ~ 41016
LO value
41017 ~ 41018
HI_HI value
41019 ~ 41020
HI value
41021 ~ 41022
Under value
41023 ~ 41024
Over value
Peak value
41025 ~ 41026
setting
SPAN calibration
41101 ~ 41102
value
The settings marked in grey are not available.
04011210
Bit I/O
Function Code 01 (Read)
Modbus
SCALE Output
00001
Stable status
00002
Zero status
00003
Gross
00004
Net
00051
Zero Band
00052
Sp1
00053
Sp2
00054
Sp3
00055
Batch Finish
00056
Under
00057
Over
00058
Unloading
00059
Hi-Hi
00060
Hi
00061
Go
00062
Lo
00063
Lo-Lo
00064
Peak ready
00065
Running
00066
ZERO calibration
00067
SPAN calibration
00068
Calibrate ERR0
00069
Calibrate ERR2
00070
Calibrate ERR6
71
Bit I/O
Function Code 05 and 15 (Write)
Modbus
SCALE Input
01001
01002
Clear zero compensation
01003
01004
Clear Tare
01005
Clear Pre-tare
Display the gross weight on
01006
main display
Display the net weight on
01007
main display
Enter/Exit the function
01008
Switch unit
01009 ~ 01028
from the 1
01050
Switch the operation modes
Totalised the current net
01051
weight and add 1 to the
totalised times
Deduct the last totalised
01052
value and deduct 1 to the
totalised times
Clear the totalised value
01053
01054
01055
01056
Discharge starts
01057
Hold mode ON/OFF
01058
Release "Hold value"
01059
Output judgement
01060
ZERO calibration
01061
SPAN calibration
ZSME400000003
Zero
Tare
mode
st
th
to 20
and times
Running
Stop

Advertisement