The oven must be mounted on the factory equipped oven
legs or on an optional oven stand. Installation on a solid
or concrete base that in any way restricts air fl ow may
void the warranty.
All clearances for a proper ventilation air supply must be
maintained to minimize fi re hazard. Do not locate the
oven immediately adjacent to any other heat-generating
appliance.
WARNING
Improper installation, alteration, adjustment, service,
cleaning, or maintenance could result in property
damage, severe injury, or death.
Read and understand the installation, operating and
maintenance instructions thoroughly before installing,
servicing, or operating this equipment.
A number of adjustments are associated with initial
installation and start-up. Adjustments must be conducted
by a qualifi ed service technician. Installation and start-
up adjustments are the responsibility of the dealer or
user. These adjustments include but are not limited to
thermostat calibration, door adjustment, and leveling.
The Platinum series oven burners are factory-adjusted
with fi xed air openings and require no fi eld adjustment.
Leveling
The oven should be leveled
before the gas supply is connected.
Level the oven from side-to-side and front-to-back with
the use of a spirit level. For ovens installed on a mobile
stand, it is important that the fl oor surface be level due to
the probability of frequent oven repositioning.
We recommend checking the level of the oven
periodically to make certain the fl oor has not
shift ed nor the oven moved.
Where automatically operated appliances are vented through a ventilating hood or exhaust
system equipped with a damper or with a power means of exhaust, provisions shall be made
to allow the equipment to operate only when the damper is open to a position to properly
vent the appliance and when the power means of exhaust is in operation. Accordance with
NFPA 54 commonwealth of massachusetts only.
MN-28665 • Rev 5 • 03/17 • ASC Series Convection Oven
CAUTION
Appliance and accessories may be
heavy. To prevent serious injury, always
use a suff icient number of trained and
experienced workers when moving or
leveling appliance and handling accessories.
Restraint Requirements
—Mobile Equipment
WARNING
RISK OF ELECTRIC SHOCK.
Appliance must be secured to building
structure. Failure to observe this precaution
may result in damage to the equipment and
severe personal injury.
Any appliance that is not furnished with a power supply
cord but includes a set of casters must be provided with
a tether. Adequate means must be provided to limit
the movement of this appliance without depending on
or transmitting stress to the electrical conduit. The
following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must of be the locking type.
3. Such mobile appliances or appliances on mobile
stands must be installed with the use of a fl exible
connector secured to the building structure.
A mounting connector for a restraining device
is located on the lower back fl ange of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the fl oor. A fl exible connector
is not supplied or available from the factory.