ELECTRICAL CONNECTIONS
4-WIRE CONNECTION: CONDUIT
WARNING
• The white middle (neutral) wire of the power
cord or 4-wire conduit must be connected to the
middle post of the main terminal block. The other
two wires of the power cord or conduit must be
connected to the outside posts of the main terminal
connection block. The fourth, ground wire (green)
must be connected to the frame of the range with
the ground screw.
− Failure to do so can result in electric shock, severe
personal injury or death.
1. Follow the instructions under "Install the conduit as
follows" on page 9 to correctly install the strain relief.
DO NOT install the conduit without a strain relief.
2. Loosen the 2 lower left and right screws from the
terminal block. (Refer to Figure 12.)
Remove the lower 2 center screws. Do not discard any
screws.
3. Remove the ground screw and bend the end of the
ground strap up so the slot is over the hole of the center
screw removed in step 2.
4. Attach the ground bare wire end to range frame and
secure it in place with the ground screw (Refer to figure
12.)
5. Insert the bare wire (white/neutral) end through the
center terminal block opening. The center screw now
attaches the bent up ground strap to the block.
6. Insert the two side bare wire ends into the left and the
right terminal block openings.
Tighten the 3 screws securely into the terminal block.
(approximately 35 - 50 IN-LB)
7. Go to page 11.
4-wire connection
Black White Red
Wire
ends
Conduit
connection plate
Ground
Screw
FIGURE 12
Terminal
block
Ground
strap
Bend strap
up and
attach
Ground
Wire