Mitsubishi Electric MXZ-3E54VA-E1 Service Manual page 11

Outdoor unit
Hide thumbs Also See for MXZ-3E54VA-E1:
Table of Contents

Advertisement

Outdoor model
Outdoor unit power supply
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity Rated frequency (Min.-Max.) 2 kW
Breaker capacity
Power input (Total) 1, 2
Running current (Total) 1, 2
Power factor (Total) 1, 2
Starting current (Total) 1, 2
Coeff cient of performance (C.O.P) (Total) 1, 2
Model
Output
Current 1, 2
Refrigeration oil (Model)
Model
Current 1, 2
Dimensions W x H x D
Weight
Air f ow (Rated)
Sound level (Rated)
Fan speed (Rated)
Refrigerant f lling capacity (R410A)
1 Measured under rated operating frequency.
2 When connected with indoor units below.
3 When the amount of current exceeds the allowed value.
MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VE
NOTE: Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
COOLING INDOOR
OUTDOOR Dry-bulb temperature 35.0 °C Wet-bulb temperature 24.0 °C
HEATING INDOOR
OUTDOOR Dry-bulb temperature 7.0 °C Wet-bulb temperature 6.0 °C
OBH723D
Dry-bulb temperature 27.0 °C Wet-bulb temperature 19.0 °C
Dry-bulb temperature 20.0 °C
m
m
m
Refer to 7 REFRIGERANT SYSTEM DIAGRAM.
m
Refer to 7 REFRIGERANT SYSTEM DIAGRAM.
Cooling
8.3 ( 3.5 - 9.2 )
A
W
2,250
A
9.9
%
A
3.68
W
A
9.30
L
SIC-81FW-D888-9, SIC-88FWJ-D888-1
A
mm
kg
3
m
/h
3,780
dB(A)
53
rpm
650
kg
11
MXZ-4E83VAHZ
Single phase
230 V, 50 Hz
2 to 4
Max. 70
Max. 25
Heating
9.0 ( 3.5 - 11.6 )
25/30 3
1,900
8.3
99
9.9
4.73
MNB33FBTMC-L
2,200
7.60
1.10 (FV50S)
0.3
950 x 1,048 x 330
87
4,620
57
770
3.9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents