M
2-S
IRAGE
TAGE
W
D
IRING
IAGRAM
3
RH Motor Wire Shown
See Detail A for LH Motor
RED
1
BLK
2
WHT
3
wht
4
blk
5
GRN
6
grn
7
To 110VAC
NOTES:
1
Wire Legend:
2
For RH Motor Configurations: Motor Red goes to Pin (1); Motor Black goes to Pin (2)
For LH Motor Configurations:
3
The SO cable from the 110VAC awning motor can only pass through a wall, it cannot be laid up in the wall
and must be connected to NM wire or individual wires in conduit no more than 6 inches past the point of entry.
4
Splitter is used only when Optional Lock-Out Sensor is installed. Connect RF Receiver directly to "EYE"
if Lock-Out is not installed.
5
Wires for the Ignition Lock-Out Sensor are not pin specific.
F
ROM
Motor
Black
Red
White
Ground
AC Power
White
Source
Black
Ground
Awning Sensor
10' Cable
Key Pad
60" Cable
Splitter
60" Cable
RF Receiver
60" Cable
Ignition Lockout
60" Cable
Notes:
1.
Cable lengths are the lengths of the furnished cables. If a connection requires a length greater than the supplied cable, the
installer must provide a terminated jumper cable from the box location to the cable end.
20
Service Manual
– S
A
INGLE
WNING
Awning #1
RED
BLK
Sensor
WHT
GRN
6
Red
Black
White
Green (Ground)
Motor Red goes to Pin (2) Black; Motor Black goes to pin (1)
T
(RH C
O
Control Box
Control Box
Control Box
Control Box
Control Box
Splitter
Splitter
Ignition Switched
+12VDC
5
12VDC
Ignition
Ground
Lockout
Sensor
(Optional)
Splitter
4
Remote
Key Pad
BLK
1
RED
2
WHT
3
wht
4
blk
5
GRN
6
grn
7
A
Detail
For LH Configuration
Reverse Red & Black Wires
)
ONFIGURATION
1
Control Box
2
3
6
4
Control Box
5
7
"AMD"
Control Box
"DSK"
Control Box
"EYE"
Control Box
Splitter
Splitter
Carefree of Colorado
RF
Receiver
UP
T
(LH C
)
O
ONFIGURATION
2
1
3
6
4
5
7
"AMD"
"DSK"
"EYE"
052588-301r4
DR012a