Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 51

Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

■When reading data in word units (word device)
Values in T100 to T102 are read.
It is supposed that 4660(1234H) is stored in T100, 2(2H) is stored in T101, and 7663(1DEFH) is stored T102.
• When communicating data in ASCII code
(Request data)
Subcommand
0
4
0
1
0
0
0
30H 34H 30H 31H
30H 30H 30H
30H 54H 4EH
(Response data)
1
2
3
4
0
0
0
31H 32H 33H 34H
30H 30H 30H
32H
T100
T101
• When communicating data in binary code
(Request data)
Device
Subcommand
code
Head
device No.
01H 04H 00H 00H 64H 00H 00H C2H 03H 00H
(Response data)
34H 12H 02H 00H EFH 1DH
T100
T101
T102
Device
Head device No.
code
0
T
N
0
0
0
1
0
30H 30H 30H
31H 30H 30H
2
1
D
E
F
31H 44H 45H
46H
T102
Number
of devices
Number of devices
0
0
0
0
3
30H 30H 30H
33H
4
4 COMMANDS
49
4.2 Device Access

Advertisement

Table of Contents
loading

Table of Contents