Download Print this page

Stellar Hearth CTL-58-AF Installation And Operating Instructions Manual

Linear direct vent gas fireplaces contemporary/transitional

Advertisement

Quick Links

CML-58-AF (Contemporary)
CTL-58-AF (Transitional)
Linear Direct Vent Gas Fireplaces
Installation and Operating Instructions
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
IMPORTANT: This appliance is only for use with the type(s) of gas indicated on the rating plate.
f i r e - p a r t s . c o m
An LP conversion kit is available when using Liquid Propane gas; order separately.
WARNING:
FIRE OR EXPLOSION HAZARD.
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
ÀDPPDEOH YDSRUV DQG OLTXLGV LQ WKH
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
'R QRW WU\ WR OLJKW DQ\ DSSOLDQFH
'R QRW WRXFK DQ\ HOHFWULFDO VZLWFK
do not use any phone in your
building.
/HDYH WKH EXLOGLQJ LPPHGLDWHO\
,PPHGLDWHO\ FDOO \RXU JDV VXSSOLHU
from a neighbor's phone. Follow the
gas supplier's instructions.
,I \RX FDQQRW UHDFK \RXU JDV
VXSSOLHU FDOO WKH ¿UH GHSDUWPHQW
— Installation and service must be
SHUIRUPHG E\ D TXDOL¿HG LQVWDOOHU
service agency or the gas supplier.
D O N O T D I S C A R D
DANGER
NEVER ALLOW CHILDREN
These products have been tested
and listed for use in the USA and
Canada by:
Underwriters Laboratories,
Northbook, IL
File #MH47882
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
TO TOUCH GLASS.
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the CTL-58-AF and is the answer not in the manual?

Questions and answers

Summary of Contents for Stellar Hearth CTL-58-AF

  • Page 1 CML-58-AF (Contemporary) CTL-58-AF (Transitional) Linear Direct Vent Gas Fireplaces Installation and Operating Instructions Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. IMPORTANT: This appliance is only for use with the type(s) of gas indicated on the rating plate.
  • Page 2 Listing Label Information & Homeowner Reference 7KLV PDQXDO VKRXOG EH UHDG WKRURXJKO\ EHIRUH LQVWDOOLQJ RU RSHUDWLQJ WKH ¿UHSODFH Installers, please leave manual for the homeowner to use for future reference. 3OHDVH KDYH WKH ¿UHSODFH PRGHO LQIRUPDWLRQ DYDLODEOH ZKHQ FRQWDFWLQJ D GHDOHU RU 6WHOODU +HDUWK IRU DGGLWLRQDO LQIRUPDWLRQ DQG VHUYLFH ZRUN 7KH PRGHO LQIRUPDWLRQ UHJDUGLQJ \RXU ¿UHSODFH FDQ EH IRXQG RQ WKH UDWLQJ SODWH ORFDWHG LQ WKH YDOYH FRQWURO DUHD XQGHUQHDWK WKH EXUQHU DVVHPEO\ RI WKH ¿UHSODFH 2QFH \RX KDYH ORFDWHG WKH UDWLQJ SODWH UHFRUG WKH IROORZLQJ LQIRUPDWLRQ DQG NHHS ZLWK \RXU UHFRUGV...
  • Page 3 TABLE OF CONTENTS /LVWLQJ /DEHO ,QIRUPDWLRQ +RPHRZQHU 5HIHUHQFH 9HQWLQJ 22-28 $ $SSURYHG 9HQWLQJ 7DEOH 2I &RQWHQWV 4" x 6-5/8" M&G Dura-Vent DV-GD and Selkirk Direct Vent System % +RUL]RQWDO 7HUPLQDWLRQV 9HQW 6\VWHP &OHDUDQFHV 6DIHW\ ,QIRUPDWLRQ 5XQ 5HTXLUHPHQWV (OERZ 5HTXLUHPHQWV &RPPRQZHDOWK RI 0DVVDFKXVHWWV 5HTXLUHPHQWV & 9HUWLFDO 7HUPLQDWLRQV 9HQW 6\VWHP &OHDUDQFHV 6SHFL¿FDWLRQV...
  • Page 4 TABLE OF CONTENTS &0/ ,QWHULRU 2SWLRQV 5HÀHFWLYH 3DQHO (UURU &RGHV 34-40 /RJ ,QVWDOODWLRQ $ 1R 3LORW )ODPH ,V (VWDEOLVKHG 'XULQJ 3LORW &0/ 2SWLRQV ,PDJHV 34-35 ,JQLWLRQ $ 5HÀHFWLYH )LUHER[ 3DQHOV ,QVWDOODWLRQ % 3LORW /RVV 2I )ODPH % /RJ 6HW 3ODFHPHQW ,GHQWL¿FDWLRQ & *ODVV /RJ 6HW ,GHQWL¿FDWLRQ ,QVWDOODWLRQ 37-40...
  • Page 5 # STL-1642 shall only be replaced temperatures and should stay away to as a complete unit, as supplied by avoid burns or clothing ignition. Stellar Hearth Products. Replacement of the glass assembly must only be ‡ Young children should be carefully SHUIRUPHG E\ D OLFHQVHG RU TXDOL¿HG...
  • Page 6 2 - COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NOTE: THE FOLLOWING REQUIREMENTS REFERENCE VARIOUS MASSACHUSETTS AND NATIONAL CODES NOT CONTAINED IN THIS MANUAL. )RU DOO VLGHZDOO KRUL]RQWDOO\ YHQWHG JDV IXHOHG HTXLSPHQW LQVWDOOHG LQ HYHU\ GZHOOLQJ EXLOGLQJ RU VWUXFWXUH XVHG LQ ZKROH RU LQ SDUW IRU UHVLGHQWLDO SXUSRV- HV LQFOXGLQJ WKRVH RZQHG RU RSHUDWHG E\ WKH &RPPRQZHDOWK DQG ZKHUH WKH VLGH ZDOO H[KDXVW YHQW WHUPLQDWLRQ LV OHVV WKDQ  IHHW DERYH ¿QLVKHG JUDGH LQ WKH DUHD RI WKH YHQWLQJ LQFOXGLQJ EXW QRW OLPLWHG WR GHFNV DQG SRUFKHV WKH IROORZLQJ UHTXLUHPHQWV VKDOO EH VDWLV¿HG INSTALLATION OF CARBON MONOXIDE DETECTORS...
  • Page 7 3 - SPECIFICATIONS A. FIREPLACE DIMENSIONS /(77(5 .(< Glass )URQW WR )ORRU WR 9HQW %DFN 2SHQLQJ 6WDQGRII DESCRIPTION +HLJKW :LGWK 'HSWK )UDPH 9HQW &HQWHU &HQWHU :LGWK :LGWK +HLJKW +HLJKW 9HUWLFDO +RUL]RQWDO INCHES       DIMENSIONS FP FP FP FP...
  • Page 8: Ohdudqfhv

    3 - SPECIFICATIONS FIRE WARNING: 7RS VWDQGRII EUDFNHW PXVW EH DWWDFKHG WR ¿UHSODFH 'R QRW UHPRYH 6WDQGRII EUDFNHWV DUH QRW ORDGEHDULQJ Non-combustible zone: Stand-offs provide 12” (305 mm) minimum clearance to header. Use only non-combustible material LQ WKLV DUHD IRU HQWLUH ZLGWK RI ¿UHSODFH 'R QRW XVH ZRRG VKHHWURFN HWF LQ WKLV ]RQH 2WKHU FOHDUDQFHV DSSO\ $OO FOHDUDQFHV must be maintained.
  • Page 9: Udplqj

    3 - SPECIFICATIONS NOTE: 7KH TXDOL¿HG LQVWDOOHU VKRXOG IROORZ WKH SURFHGXUH EHVW VXLWHG IRU WKH LQVWDOODWLRQ C. INSTALLATION OVERVIEW )UDPH DQ RSHQLQJ IRU ¿UHSODFH DOORZLQJ IRU YHQW LQVWDOODWLRQ DQG W\SH RI LQVWDOODWLRQ FRUQHU ÀDW ZDOO W\SH RI IURQW WR EH XVHG DQGRU FOHDQ IDFH DSSOLFDWLRQ  ,I PDVRQU\ RSWLRQDO ZLOO EH XVHG SUHSDUH IRXQGDWLRQ IRU WKH PDVRQU\ ORDG $ OLQWHO LV UHTXLUHG WR VXSSRUW WKH DGGHG ZHLJKW DERYH WKH ¿UHSODFH ,QVWDOO KHDUWK LI GHVLUHG...
  • Page 10: Udplqj

    3 - SPECIFICATIONS E. DECORATIVE FRONTS AND HEARTH - VERIFY PRIOR TO FRAMING ,03257$17 .HHS WKH RXWHU GLPHQVLRQV RI WKH GHFRUDWLYH IURQW DQG KHDUWK VSHFL¿FDWLRQV LQ FRQVLGHUDWLRQ XS IURQW ZKHQ SODQQLQJ WKH IUDPLQJ DQG ¿QLVKLQJ RI WKH ¿UHSODFH 6HH 6HFWLRQ  )LQLVKLQJ 7KH :DOO CLEAN TRIM FRONT AND HEARTH &OHDQ 7ULP GLPHQVLRQV DUH  [  PP [ PP DQG LV DQ LQVLGH ¿W IURQW ACCENT DECORATIVE FRONT...
  • Page 11 4 - PREPARE THE FIREPLACE FIRE WARNING: STAND-OFFS PROVIDE 12” (305 mm) MINIMUM CLEARANCE TO HEADER. USE ONLY NON-COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF FIREPLACE. DO NOT USE WOOD, SHEETROCK, ETC., IN THIS ZONE. NOTE: TOP STAND-OFF BRACKETS MUST BE FORMED AND ATTACHED PRIOR TO POSITIONING FIRE PLACE INTO FRAMED OPENING.
  • Page 12 5 - FRAMING A. WALL ENCLOSURE ROUGH OPENING NOTE: 1RQFRPEXVWLEOH IDFLQJ PDWHULDO PD\ EH DSSOLHG XS WR EXW VKRXOG QRW EH DSSOLHG RYHU WKH EODFN ¿UHSODFH IDFH 7KH IURQW ZLOO FRYHU WKH EODFN ¿UHSODFH IURQW 'R QRW REVWUXFW WKH ÀRZ RI YHQWLODWLRQ DLU NOTE: )UDPLQJ GLPHQVLRQV VKRXOG DOORZ IRU ZDOO FRYHULQJ WKLFNQHVV DQG ¿UHSODFH IDFLQJ PDWHULDOV :KHQ XVLQJ D KHDUWK adjust rough opening size as necessary to maintain at least minimum clearance requirements.
  • Page 13 5 - FRAMING 'HWHUPLQH H[DFW SRVLWLRQ RI \RXU ¿UHSODFH LQFOXGLQJ KHDUWK KHLJKW ZLGWK DQG GHSWK ,I SRVVLEOH SODFH ¿UHSODFH LQ VXFK D PDQQHU WKDW YHQW WHUPLQDWLRQ ZLOO EH SODFHG EHWZHHQ WZR VWXGV HOLPLQDWLQJ WKH QHHG IRU DGGLWLRQDO IUDPLQJ ,I PDVRQU\ LV WR EH XVHG RSWLRQDO  SUHSDUH WKH QHFHVVDU\ IRXQGDWLRQ IRU WKH PDVRQU\ ORDG :KHQ PDVRQU\ FRQVWUXFWLRQ LV EHLQJ XVHG D OLQWHO PXVW EH XVHG RYHU WRS RI ¿UHSODFH WR VXSSRUW WKH DGGHG ZHLJKW %XLOG KHDUWK WR GHVLUHG VL]H DQG KHLJKW ,I D KHDUWK H[WHQVLRQ LV GHVLUHG FRPEXVWLEOH PDWHULDO PD\ EH XVHG 127( &RQVLGHU KHLJKW RI KHDUWK H[WHQVLRQ ¿QLVKLQJ PDWHULDO VWRQH EULFN HWF ZKHQ EXLOGLQJ ¿UHSODFH SODWIRUP 7KH ERWWRP...
  • Page 14: Hqwlqj

    5 - FRAMING D. VERTICAL TERMINATION )ROORZ YHQW SLSH PDQXIDFWXUHU¶V LQVWDOODWLRQ LQVWUXFWLRQV XVLQJ DSSURYHG GLUHFW YHQW SLSH IRU YHUWLFDO WHUPLQDWLRQV A minimum 1” (25 mm) clearance on all sides of vertical vent pipe must be maintained. 127( $ YHQWLQJ ¿UHVWRS PXVW EH XVHG RQ DOO KRUL]RQWDO YHQW UXQV Follow instructions in Section 11 - Venting (Fig.11D). &2/' $,5 127( &ROG DLU WUDQVIHU DUHD 7KH VXUURXQGLQJ ¿UHSODFH FKDVH PXVW FRPSO\ ZLWK DOO FOHDUDQFHV DV RXWOLQHG LQ WKLV manual and be constructed in compliance with local building codes.
  • Page 15 5 - FRAMING F. NAILING FLANGE ASSEMBLY & INSTALLATION CAUTION: NEVER PERMANENTLY REMOVE THESE ASSEMBLIES FROM FIREPLACE . THEY MUST BE SECURED IN PLACE REGARDLESS OF FINISH MATERIAL USED. 7R ,QVWDOO 1DLOLQJ )ODQJHV %HQG SHUIRUDWLRQ RQ QDLOLQJ ÀDQJH XQWLO SDUDOOHO ZLWK ¿UHSODFH IDFH 'R QRW RYHUEHQG WRZDUG ¿UHSODFH IDFH 3RVLWLRQ IUDPLQJ DJDLQVW VWDQGRII 6HFXUH ZLWK QDLOV RU VFUHZV 6HH SDJHV  IUDPLQJ )XOO\ LQVWDOOHG QDLOLQJ...
  • Page 16 6 - MANTEL REQUIREMENTS NON-COMBUSTIBLE ZONE ◄ Non-Combustible Zone: No materials allowed on top of the ▲ fireplace within shaded area for entire width and depth of fireplace. ▲ ▲ This air space MUST remain open. 28-1/8 ▲ (715 mm) ◄...
  • Page 17 7 - GLASS FRAME ASSEMBLY A. REMOVE GLASS FRAME ASSEMBLY ,I GHFRUDWLYH IURQW LV DOUHDG\ LQ SODFH UHPRYH WKH IURQW RU PHVK VFUHHQ &/($1 75,0 $1' $&&(17 )52176 5HPRYH WKH IURQW E\ OLIWLQJ DQG XQKRRNLQJ WKH IURQW (0,1(1&( $1' ,163,5$7,21 )52176 5HPRYH WKH PHVK E\ OLIWLQJ XS RQ WKH PHVK XS DQG SXOOLQJ WKH ERWWRP IUHH RI WKH ORZHU VORWV /RFDWH VSULQJORDGHG KDQGOHV VHFXULQJ JODVV IUDPH DVVHPEO\ DW WRS ERWWRP RI ¿UHER[ 8VLQJ WKH SXOO WRRO IURP WKH PDQXDO EDJ SXOO ERWWRP KDQGOHV RXW DQG µGRZQ¶...
  • Page 18 8 - OPTIONAL FK160 FAN KIT INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BE A QUALIFIED INSTALLER. ELECTRICAL WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES. ELECTRICAL WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEP- TACLE.
  • Page 19 10 - GAS LINE CONNECTION A. GAS CONVERSION 7KLV ¿UHSODFH LV PDQXIDFWXUHG IRU XVH ZLWK 1DWXUDO *DV $Q /3 FRQYHUVLRQ NLW LV DYDLODEOH LPCK-CXL iV VROG VHSDUDWHO\ )ROORZ LQVWUXFWLRQV IRXQG LQ 6HFWLRQ  RU LQFOXGHG ZLWK FRQYHUVLRQ NLW &$87,21 ,QVWDOODWLRQ RI WKH JDV OLQH PXVW RQO\ EH GRQH E\ D TXDOL¿HG SHUVRQ LQ DFFRUGDQFH ZLWK ORFDO EXLOGLQJ FRGHV LI DQ\ ,I QRW IROORZ $16,  &RPPRQZHDOWK RI 0DVVDFKXVHWWV ,QVWDOODWLRQ PXVW EH GRQH E\ D OLFHQVHG SOXPEHU RI JDV ¿WWHU NOTE: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.
  • Page 20 11 - VENTING NOTE: Consult the local and national installation codes to assure adequate combustion and ventilation air is available. 127( )ODPH KHLJKW DQG DSSHDUDQFH ZLOO YDU\ GHSHQGLQJ XSRQ YHQWLQJ FRQ¿JXUDWLRQ DQG W\SH RI IXHO XVHG 9HQWLQJ UHTXLUH- ments apply to both Natural and LP gas NOTE: MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL.
  • Page 21: Ins_Clx58-Af Rev D

    11 - VENTING C. VERTICAL TERMINATIONS VENT SYSTEM CLEARANCES ALL APPROVED VENTING BOTTOM SIDES VERTICAL 1 inch (25mm) 1 inch (25mm) 1 inch (25mm) TERMINATIONS MINIMUM: 10 ft. (3.05 m) + termination cap. MAXIMUM: 40 ft. (9.14 m) + termination cap. ELBOWS )RU HDFK DGGLWLRQDO ƒ...
  • Page 22 11 - VENTING D. WALL PASS-THROUGH NOTE: M & G DURAVENT 46DVA-WT WITH HEAT SHIELD OR DURAVENT VERTICAL 46DVA-FS WALL PASS-THRU (OR SELKIRK EQUIVALENT) MUST BE USED ON ALL HORIZONTAL VENT TERMINATIONS. THIS INCLUDES BOTH INTERIOR AND EXTERIOR WALLS. FOLLOW INSTRUCTIONS BELOW. A = 9"...
  • Page 23 11 - VENTING E. HORIZONTAL & VERTICAL COMBINATION TERMINATIONS 0$;,080  IW  P YHUWLFDO   IW  P KRUL]RQWDO  FDS 0HDVXUHPHQWV DUH IURP WKH FHQWHU OLQHV RQ WKH SLSH WR WKH EDFN RI WKH WHUPLQDWLRQ FDS SODWH (6.1 m) 10 12 18 20 22...
  • Page 24 11 - VENTING F. HORIZONTAL TERMINATION VENT CAP LOCATION & CLEARANCES This gas appliance must not be connected to a chimney serving any other appliance. ‡ 7HUPLQDWLRQV DJDLQVW YLQ\O VLGLQJ PXVW XVH D YLQ\O VLGLQJ SURWHFWRU )ROORZ LQVWUXFWLRQV LQFOXGHG ‡ '2 127 5(&(66 7(50,1$7,21 .,7 ,172 2876,'( %8,/',1* 0$7(5,$/6  LH EULFN VWRQH VLGLQJ HWF ,I QHFHVVDU\ H[WHQG IUDPLQJ VR WKDW WHUPLQDWLRQ NLW ZLOO EH H[SRVHG RQFH EXLOGLQJ PDWHULDOV DUH LQVWDOOHG ‡...
  • Page 25 11 - VENTING F. HORIZONTAL TERMINATION VENT CAP LOCATION & CLEARANCES NOTE: A vent cannot be located directly above a side-walk or paved driveway that is located between two single family dwellings and serves both dwellings. Inside Corner Outside Corner Recessed Location f i r e - p a r t s .
  • Page 26 11 - VENTING G. VERTICAL VENT CAP LOCATION AND CLEARANCES ROOF PITCH (Figure 11.G) H (Min.) Ft. H (Min.) M FLAT TO 6/12 1.0* 0.30 OVER 6/12 TO 7/12 1.25* 0.38 * = 3 foot mininum in OVER 7/12 TO 8/12 1.5* 0.46 snowy regions...
  • Page 27 12 - FINISHING THE WALL A. NON-COMBUSTIBLE ZONE NOTE: DO NOT COVER THE NON-COMBUSTIBLE BOARD WITH COMBUSTIBLE FINISHING MATERIAL $&78$/ )5217 ',0(16,216 &OHDQ 7ULP  [  Non-combustible board included, shipped on back of unit 62-1/4” x 13-1/2” $FFHQW  [  (1,581mm x 343mm) (PLQHQFH  [  ,QVSLUDWLRQ  [ ...
  • Page 28 12 - FINISHING THE WALL C. ACCENT DECORATIVE FRONT CAUTION: DO NOT COVER THE NON-COMBUSTIBLE BOARD WITH COMBUSTIBLE FINISHING MATERIAL Thin Finishing Material - Up To 1" (25mm) Thick Stop finishing material at the top of the unit. ▼ ▲ Finishing materials 24-1/4”...
  • Page 29 12 - FINISHING THE WALL D. EMINENCE AND INSPIRATION DECORATE FRONTS CAUTION: DO NOT COVER THE NON-COMBUSTIBLE BOARD WITH COMBUSTIBLE FINISHING MATERIAL Thin Finishing Material - Up To 1" (25mm) Thick Center the unit in a 61-1/2” x 27-3/8” (1,562mm x 695mm) opening in the finishing material.
  • Page 30 13 - CTL-58 LOG SET IDENTIFICATION & INSTALLATION NOTE: If converting to LP (propane) gas do so now before installing log set in Section 24. Follow instructions included with kit. &$87,21 'R QRW SODFH ORJV GLUHFWO\ RYHU EXUQHU SRUW KROHV ,PSURSHU ORJ SODFHPHQW PD\ DIIHFW ÀDPH DSSHDUDQFH DQG FDXVH excessive soot to build up on logs and glass.
  • Page 31 13 - CTL-58 LOG SET INSTALLATION B. CTL-58 LOG SET INSTALLATION Logs 5-7 are place behind the grate. CAUTION: THE PILOT MUST NOT BE COVERED BY ANY OF THE LOGS. Log 5 )DU 5LJKW %RWWRP /RJ Log 6 /HIW 7ZLJ Log 7 5LJKW 7ZLJ Figure 13B.2 Step 4—Log 5...
  • Page 32 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION CML-58 INTERIOR OPTIONS CML-58-AF with any color of glass media 6NLS SDUW $ &0/ 5()/(&7,9( ),5(%2; 3$1(/ ,167$//$7,21 DQG JR WR WKH JODVV PHGLD GDPPHGLD DQG EXUQLQJ HPEHUV VHW XS LQ SDUW % &0/ /2* 6(7 ,'(17,),&$7,21 ,167$//$7,21  f i r e - p a r t s .
  • Page 33 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION CML-58 INTERIOR OPTIONS CML-58-AF (complete) with CML-GLASS-WALLS, CML-GLASS-LOGS and glass media 3URFHHG WR SDUW $ &0/ 5()/(&7,9( ),5(%2; 3$1(/ ,167$//$7,21 FRPSOHWLQJ HDFK VWHS LQ WKH LQVWDOODWLRQ RI WKH PLUURUHG ¿UHER[ SDQHOV DQG LQ SDUW % &0/ /2* 6(7 ,'(17,),&$7,21 ,167$//$7,21 IRU WKH JODVV ORJ VHW JODVV PHGLD GDPPHGLD DQG EXUQLQJ HPEHUV LQVWDOODWLRQ f i r e - p a r t s .
  • Page 34 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION A. CML-58 REFLECTIVE FIREBOX PANELS INSTALLATION (Figure 14A) You MUST wear gloves before handling the glass pieces. This will reduce the risk of injury if there should be any sharp edges VWLOO RQ WKH JODVV DQG WR KHOS NHHS ¿QJHU SULQWV RII WKH JODVV SLHFHV Take care when handling the glass pieces to avoid breakage.
  • Page 35 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION B. CML-58 LOG SET IDENTIFICATION & INSTALLATION ATTENTION: You MUST wear gloves before handling the glass pieces. This will reduce the risk of injury if there should be any VKDUS HGJHV VWLOO RQ WKH JODVV DQG WR KHOS NHHS ¿QJHU SULQWV RII WKH JODVV SLHFHV CAUTION: Take care when handling the glass pieces to avoid breakage.
  • Page 36 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION ATTENTION: You MUST wear gloves before handling the glass pieces. This will reduce the risk of injury if there should be any VKDUS HGJHV VWLOO RQ WKH JODVV DQG WR KHOS NHHS ¿QJHU SULQWV RII WKH JODVV SLHFHV Glass Log Set 2 ▲...
  • Page 37 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION ATTENTION: You MUST wear gloves before handling the glass pieces. This will reduce the risk of injury if there should be any VKDUS HGJHV VWLOO RQ WKH JODVV DQG WR KHOS NHHS ¿QJHU SULQWV RII WKH JODVV SLHFHV Glass Set 4 Log 8 - Front Middle, Top ▲...
  • Page 38 14 - CML-58 INTERIOR OPTIONS, REFLECTIVE LINER & LOG SET INSTALLATION B. CML-58 LOG SET IDENTIFICATION & INSTALLATION Glass Log Set 6 Log 11 - Back Right, Base Log 12 - Back Right, Top ▲ ▲ 6” 4-3/8” (152 mm) (111 mm) ▼...
  • Page 39 15 - CML-58 LIGHTBULB REPLACEMENT &$87,21 0$.( 685( /,*+76 $5( 6(7 72 ³2´ 2)) $1' 32:(5 ,6 ',6&211(&7(' If the burner light bulb needs replacing: 5HPRYH WKH GHFRUDWLYH IURQW RI IURQW DFFHVV SDQHO 5HPRYH WKH YDOYH FRYHU WR DFFHVV WKH DUHD XQGHUQHDWK WKH ¿UHER[ 5HPRYH WKH ZLQJ QXWV RQ HDFK VLGH RI WKH OLJKW VRFNHW /RZHU WKH VRFNHW VWUDLJKW GRZQ :HDULQJ JORYHV SXOO WKH OLJKW EXOE RXW RI WKH VRFNHW 5HSODFH WKH OLJKW EXOE ZLWK D QHZ RQH RI WKH H[DFW W\SH  PDNLQJ VXUH WKH ZKLWH JDVNHW LV LQ SODFH DURXQG WKH EXOE...
  • Page 40 16 - VALVE & PILOT ASSEMBLY COMPONENTS PLEASE NOTE: AF valve components started with either Serial # 10 or 2014. If you have a unit manufactured prior to the change, please refer to earlier Installation and Operating Instructions and verify serial number before ordering replacement parts.
  • Page 41 16 - VALVE & PILOT ASSEMBLY COMPONENTS B. IPI PILOT ASSEMBLY C. IPI GAS VALVE FLAME SENSOR IGNITOR PILOT NUT f i r e - p a r t s . c o m Figure 16C Figure 16B C. EXTENDED CONTROL MODULE D.
  • Page 42 17 - REMOTE CONTROL OPERATION INSTRUCTIONS This remote is used with American Flame valve components starting with either Serial # 10 or 2014. If you have a unit manufactured with a Serial # starting with 13, you need a remote for the SIt valve system and please refer earlier Installation and Operating Instructions for more information.
  • Page 43 17- REMOTE CONTROL OPERATION B. REMOTE CONTROL INFORMATION ELECTRICAL WARNING Electrical wiring must be installed by a licensed electrician. ‡ Do NOT wire 110V to wall switch. ‡ Uninterrupted or continuous power is required at all times in IPI systems EXCEPT when using battery back-up. ‡...
  • Page 44 17 - REMOTE CONTROL OPERATION E. MATCHING SECURITY CODES %HIRUH PDWFKLQJ VHFXULW\ FRGHV PDNH VXUH 9 $& LV FRQQHFWHG DQG SRZHUHG WR ¿UHSODFH DQG KDQG KHOG UHPRWH FRQWURO LV LQVWDOOHG ZLWK  EDWWHULHV ,W PD\ EH QHFHVVDU\ WR SURJUDP PDLQ FRQWURO PRGXOH WR /($51 WKH VHFXULW\ FRGH RI WKH KDQG KHOG UHPRWH FRQWURO XSRQ LQLWLDO XVH LI EDWWHULHV DUH UHSODFHG RU LI D UHSODFHPHQW UHPRWH FRQWURO LV SXUFKDVHG IURP \RXU GHDOHU :KHQ PDWFKLQJ VHFXULW\ FRGHV EH VXUH VOLGH EXWWRQ RQ PDLQ FRQWURO PRGXOH LV LQ 5(027( WKH FRGH ZLOO QRW ³/($51´...
  • Page 45 17 - REMOTE RECEIVER INFORMATION H. CELSIUS/FAHRENHEIT CONVERSION 3UHVV 83 DQG '2:1 NH\V VLPXOWDQHRXVO\ WR FKRRVH &HOVLXV RU )DKUHQKHLW I. IMPORTANT SAFETY FEATURE 7KLV V\VWHP KDV D PD[LPXP URRP WHPSHUDWXUH OLPLW RI ƒ ) ƒ & LQ ERWK PDQXDO DQG WKHUPRVWDW PRGHV :KHQ URRP WHPSHUDWXUH LV DW RU DERYH WKLV SRLQW WKH V\VWHP ZLOO VKXW GRZQ DQG WKH KDQG KHOG UHPRWH FRQWURO ZLOO UHDG OFF ,I \RX WXUQ WKH V\VWHP ON ZKHQ URRP WHPSHUDWXUH LV VWLOO DW RU DERYH WKLV WHPSHUDWXUH WKH V\VWHP ZLOO DJDLQ VKXWGRZQ DIWHU  PLQXWHV ZKHQ URRP WHPSHUDWXUH LV UHFDOFXODWHG J.
  • Page 46 17 - REMOTE CONTROL OPERATION M. FAN MODE 7KLV UHPRWH ZLOO RSHUDWH WKH IDQ DOORZLQJ IRU  GLIIHUHQW VSHHG OHYHOV :KHQ WKH FAN EXWWRQ LV SUHVVHG FAN OHYHO VHWWLQJ ZLOO ÀDVK RQ WKH LCD VFUHHQ 3UHVV UP RU DOWN EXWWRQV WR VHOHFW GHVLUHG IDQ VSHHG OHYHO ,I QR DGMXVWPHQW LV PDGH ZLWKLQ  VHFRQGV WKH FRQWURO ZLOO H[LW IXQFWLRQ VHWWLQJ PRGH DQG LCD GLVSOD\ ZLOO UHWXUQ WR QRUPDO YLHZ Figure 17M...
  • Page 47 17 - REMOTE CONTROL OPERATION P. THERMO (THERMOSTATE) MODE 7KLV UHPRWH IHDWXUH DOORZV \RX WR WKHUPRVWDWLFDOO\ FRQWURO WKH ¿UHSODFH ZKHQ KDQG KHOG UHPRWH LV VHW WR THERMO PRGH 6HW 7HPSHUDWXUH 5DQJH Û) Û& WR Û) Û&  6HW UHPRWH WR THERMO PRGH E\ SUHVVLQJ MODE EXWWRQ 7KH VPDOOHU SET ZLQGRZ RI QXPEHUV DSSHDUV RQ WKH LCD VFUHHQ 7KH ¿UVW SET QXPEHU ZLOO UHDG Û) 3UHVV UP EXWWRQ WR GHVLUHG VHW URRP WHPSHUDWXUH :LWKLQ  VHFRQGV ¿UHSODFH ZLOO RSHUDWH WR WKDW 6HW...
  • Page 48: Ljkwlqj

    18 - LIGHTING & SHUTDOWN FOR YOUR SAFETY - READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. DUE TO HIGH SURFACE TEMPERATURES, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. 7KLV DSSOLDQFH QHHGV IUHVK DLU IRU VDIH RSHUDWLRQ DQG PXVW EH LQVWDOOHG VR WKHUH DUH SURYLVLRQV IRU DGHTXDWH FRPEXVWLRQ DQG YHQWLODWLRQ DLU 7KLV LV D GLUHFW YHQW DSSOLDQFH ZKLFK PHDQV LW JHWV  RI LWV DLU IURP WKH RXWVLGH WKURXJK WKH WHUPLQDWLRQ FDS ,W LV LPSRUWDQW WR PDNH VXUH WKH WHUPLQDWLRQ FDS...
  • Page 49 18 - LIGHTING & SHUTDOWN A. IF FIREPLACE FAILS TO LIGHT STOP! Read safety information on previous page and front cover of this manual before continuing. 7XUQ RII DOO HOHFWULFDO SRZHU WR ¿UHSODFH 3UHVV KDQG KHOG UHPRWH 02'( EXWWRQ WR 2)) :DLW ¿YH  PLQXWHV WR DOORZ DQ\ JDV WKDW PD\ KDYH DFFXPXODWHG LQVLGH ¿UHER[ WR HVFDSH ,I \RX WKHQ VPHOO JDV 6723 )ROORZ VDIHW\ LQIRUPDWLRQ RQ IURQW FRYHU DQG RQ SUHYLRXV SDJH RI WKH LQVWDOODWLRQ...
  • Page 50 19 - PRESSURE TESTING NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi. NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas line at test pressures equal to or less than ½...
  • Page 51 21 - FINALIZING THE INSTALLATION A. FLAME APPEARANCE )ODPH DSSHDUDQFH LV DIIHFWHG E\ VHYHUDO IDFWRUV LQFOXGLQJ DOWLWXGH YHQWLQJ FRQ¿JXUDWLRQ DQG IXHO TXDOLW\ $OWKRXJK WKH YHQWXUL VHWWLQJ KDV EHHQ IDFWRU\ VHW DGMXVWPHQWV PD\ EH QHFHVVDU\ IRU RSWLPDO SHUIRUPDQFH DQG YLVXDO DHVWKHWLFV :KHQ ¿UHSODFH LV ¿UVW OLW WKH ÀDPHV ZLOO EH EOXH )ODPHV ZLOO JUDGXDOO\ WXUQ \HOORZLVKRUDQJH GXULQJ ¿UVW  PLQXWHV RI RSHUDWLRQ ,I ÀDPHV UHPDLQ EOXH RU EHFRPH GDUN RUDQJH ZLWK HYLGHQFH RI VRRWLQJ EODFN WLSV  WKH EXUQHU WXEH YHQWXUL PD\ QHHG DGMXVWPHQW WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING SHOULD ONLY BE PERFORMED BY A QUALIFIED...
  • Page 52 21 - FINALIZING THE INSTALLATION E. RESTRICTOR USAGE ‡ 7XUQ ¿UHSODFH RQ DQG DOORZ WR EXUQ IRU  PLQXWHV ‡ ,I ÀDPHV LQGLFDWH WKHUH LV H[FHVVLYH GUDIW ÀLFNHULQJ VKRUW ÀDPHV  D UHVWULFWRU PD\ EH QHFHVVDU\ ‡ ,I ÀDPHV LQGLFDWH LQVXI¿FLHQW GUDIW OLIWLQJ RU JKRVWLQJ ÀDPHV  D SUHYLRXVO\ LQVWDOOHG UHVWULFWRU PD\ QHHG WR EH PRGL¿HG RU UHPRYHG WARNING: TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO COOL BEFORE MAKING ANY ADJUSTMENTS AND / OR INSTALLATIONS.
  • Page 53 ‡ 'R QRW RSHUDWH WKLV ¿UHSODFH ZLWK JODVVIUDPH DVVHPEO\ UHPRYHG FUDFNHG RU EURNHQ ‡ The glass assembly, part #STL-1642, shall only be replaced as a complete unit, as supplied by Stellar Hearth Products. ‡ 5HSODFHPHQW RI JODVV IUDPH DVVHPEO\ PXVW RQO\ EH SHUIRUPHG E\ D OLFHQVHG RU TXDOL¿HG VHUYLFH SHUVRQ DO NOT SUBSTITUTE MATERIALS.
  • Page 54: Urxeohvkrrwlqj

    23 - TROUBLESHOOTING A. MAIN CONTROL MODULE WILL NOT LEARN TRANSMITTER ‡ (QVXUH 5(027(2)) VZLWFK RQ VLGH RI PDLQ FRQWURO PRGXOH LV VHW WR 5(027( ‡ 0DNH VXUH EDWWHULHV LQ WKH KDQG KHOG UHPRWH DUH LQVWDOOHG LQ WKH SURSHU GLUHFWLRQ DQG DUH QRW GUDLQHG ‡...
  • Page 55 23 - TROUBLESHOOTING F. FLAME HEIGHT ADJUSTMENTS NOT WORKING/WORKS BACKWARDS ‡ &KHFN IXQFWLRQDOLW\ ZLWK DOO WUDQVPLWWHUV WR GHWHUPLQH LI WKHUH LV DQ LVVXH ZLWK WKH PDLQ FRQWURO V\VWHP RU DQ LQGLYLGXDO WUDQVPLWWHU ,I WKH LVVXH LV ZLWK DQ LQGLYLGXDO WUDQVPLWWHU PDNH VXUH EDWWHULHV LQ KDQG KHOG UHPRWH DQG EDFNXS EDWWHU\ SDFN DUH LQVWDOOHG SURSHUO\ DQG DUH QRW GUDLQHG G.
  • Page 56 24 - LPC - CXL CONVERSION KIT INSTRUCTIONS WARNING 7KLV FRQYHUVLRQ NLW VKDOO EH LQVWDOOHG E\ D TXDOL¿HG VHUYLFH DJHQF\ LQ DFFRUGDQFH ZLWK WKH PDQXIDFWXUHV LQVWUXFWLRQV DQG DOO DSSOLFDEOH FRGHV DQG UHTXLUHPHQWV RI WKH DXWKRULW\ KDYLQJ MXULVGLFWLRQ ,I WKH LQIRUPDWLRQ LQ WKHVH LQVWUXFWLRQV LV QRW IROORZHG H[DFWO\ D ¿UH H[SORVLRQ RU SURGXFWLRQ RI FDUERQ PRQR[LGH PD\ UHVXOW FDXVLQJ SURSHUW\ GDPDJH SHUVRQDO LQMXU\ RU ORVV RI OLIH 7KH TXDOL¿HG VHUYLFH agency is responsible for proper installation of the kit.
  • Page 57 24 - LPC - CXL CONVERSION KIT INSTRUCTIONS D. GAS TYPE CONVERSION 3UHVV DQG KROG WKH /($51 %87721 RQ 0DLQ &RQWURO 0RGXOH IRU  PRESSURE REGULATOR CAP VHFRQGV $ EHHS ZLOO EH KHDUG OHWWLQJ \RX NQRZ WKH SURFHGXUH KDV EHHQ FRPSOHWHG If converting from NAT to LP gas: RQH  VHFRQG ORQJ EHHS If converting from LP to NAT gas: WKUHH  VHFRQGV ORQJ EHHS E.
  • Page 58 24 - LPC - CXL CONVERSION KIT INSTRUCTIONS G. TESTING FOR LEAKS. 7XUQ RQ WKH JDV DQG HOHFWULFLW\ WR WKH ¿UHSODFH /LJKW WKH SLORW E\ SUHVVLQJ WKH 3LORW EXWWRQ &2167$17 3,/27 ZLOO DSSHDU RQ WKH /&' VFUHHQ (Figure 19J). 7KH SLORW VKRXOG OLJKW 8VLQJ D VROXWLRQ RI VRDS\ ZDWHU FKHFN WKH SLORW WXEH DQG QXW DUHD IRU OHDNV ,I QR OHDNV DUH SUHVHQW H[WLQJXLVK WKH SLORW DQG SURFHHG 127( ,I WKH ¿UHSODFH ZLOO QRW RSHUDWH IROORZ WKH LQVWUXFWLRQV 7851,1* 2)) *$6 72 ),5(3/$&( DQG FDOO \RXU VHUYLFH...
  • Page 59 Original CTL-58 & CML-58, Serial # starting with "10" (AF system). CTL-58-S &CML-58-S, Serial # starting with "13" (SIT system). LG-MR /,48,' 0(5&85< CTL-58-AF & CML-58-AF, Serial # starting with "14" (AF system). LG-TQ TEQUILA 3OHDVH UHIHU WR HDUOLHU UHYLVLRQV RI ,QVWDOODWLRQ...
  • Page 60: Limited Lifetime Warranty

    Limited Lifetime Warranty Stellar Hearth Products, a brand of Big Woods Hearth Products Inc, warrants the following components for life to the original owner, subject to proof of purchase: Firebox, Heat Exchanger, Combustion Chamber, Grate and Stainless Steel Burners. Electrical components and wearable parts (gas valve, blowers, wiring, switches, remote controls, gasketing, and pilot assembly) are covered and will be provided free of charge for a period of one year from date of purchase.

This manual is also suitable for: