Edid Upgrade Procedure - Elo Touch Solutions ET1517L Service Manual

Hide thumbs Also See for ET1517L:
Table of Contents

Advertisement

2.1.4 EDID Upgrade Procedure

Step 1. Select "IIC" and key in "6e 51 82 e0 00 5d" as following, then, click on "Send Data" to
disable EDID EEPROM write protect.
Note: DC off monitor when RTD Customer Tool sends write pr
otect command to monitor
Fill the number
"6e,51,82,e0,00,5d"
Service Manual: ET1517L, ET1717L
ES600904 Rev B, Page 30 of 44