1.1 SPECIFICATIONS

Item
Cooling capacity (1)
Power supply
Power
consumption
Running
current
Operation
data (1)
Inrush current
COP
Noise
Cooling
level
Exterior dimensions (Height x Width x Depth)
Exterior appearance
(Munsell color)
Net weight
Compressor type & Q'ty
Motor (Starting method)
Refrigerant oil
Refrigerant
equipment
Refrigerant (4)
Heat exchanger
Refrigerant control
Fan type & Q'ty
Motor
Air handling
Air flow
equipment
Fresh air intake
Air filter, Quality / Quantity
Shock & vibration absorber
Operation switch
Operation
Room temperature control
control
Operation Display
Safety devices
Refrigerant piping size (O.D)
Connecting method
Attached length of piping
Installation
data
Insulation for piping
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Drain hose
Power cable
Recommended breaker size
Connection wiring
Accessories (included)
Option parts
Note (1) The data are measured at the following conditions.
Item
Operation
Cooling
(2) This air-conditioner is manufactured and tested in conformity with the TISI.
(3) The operation data are applied to the 220V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even for the short piping.)
Model
W
Cooling
kW
Cooling
A
Cooling
Sound level
dB(A)
mm
kg
kW
kg
W
3
Cooling
m
/min
mm
m
m
A
Size x Core number
Connecting method
Indoor air temperature
DB
WB
27˚C
19˚C
Indoor unit SRK10CNV
1 Phase, 220 V, 50Hz
40
268 x 790 x 213
Fine snow
(8.0Y 9.3/0.1) near equivalent
8.5
0.35 (SUNISO 4GSI or ATMOS NM56)
R22 0.58 (Pre-Charged up to the piping length of 7.5m)
Louver fins & inner grooved tubing
Tangential fan x 1
16
10.0
Not possible
Polypropylene net (washable) x 2
Wireless remote control
Microcomputer thermostat
RUN : Green, TIMER : Yellow, HI POWER : Green,
Frost protection, Fan motor error protection,
Internal thermostat (for Compressor)
Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")
Liquid line : 0.4
Gas line : 0.33
Necessary (Both sides), independent
Max.5 (Outdoor unit is higher)
Max.5 (Outdoor unit is lower)
Connectable (VP 16)
2.5m (3 Cores wih Earth)
2
1.5mm
x 3 cores (Including earth cable)
Terminal block (Screw fixing type)
Clean filter (Natural enzyme filterx1, Photocatalytic washable deodorizing filterx1)
Outdoor air temperature
DB
WB
35˚C
24˚C
JIS C 9612, TISI 1155, 2134, 812

-
-
'14•SRK-T-153
SRK10CNV
Outdoor unit SRC10CNV
2800
0.77
3.5
18
3.64
45
540 x 780 (+62) x 290
Stucco white
(4.2Y 7.5/1.1) near equivalent
28
RMC201A011 (Rotary type) x 1
0.69 (Line starting)
Louver fins & inner grooved tubing
Capillary tubes
Propeller fan x 1
14.5
26.5
Cushion rubber (for compressor)
ECONO : Orange
Flare connecting
Max. 15
20
Mounting kit,
The pipe length is 7.5m.
Standards

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents