14.5

Maintenance of fuel filter

① Turn the fuel lever to "OFF" position, and remove fuel filter cup.
Remove the filter.
Blow from the counter direction of arrow with an air gun
and remove fuel filter cup
② Clean fuel filter cup completely
③ Fix the new rubber spacer and fuel cup
14.6

Storage turn off the fuel valve

⑴ Screw off fuel filler cup and pour off all the fuel in the cup
⑵ Open fuel valve, drain off fuel in the tank.
⑶ Replace the gasket and screw the cup on tightly.