Summary of Contents for Panasonic KX-TGA106CM

  • Page 1 ORDER NO. KM40903853CE Telephone Equipment KX-TG1061CM Model No. KX-TGA106CM Expandable Digital Corded/Cordless Answering System M: Metallic Grey Version (for Canada) © Panasonic Communications Co., Ltd. 2009. Unauthorized copying and distribution is a violation of law.
  • Page 2 KX-TG1061CM/KX-TGA106CM...
  • Page 3: Table Of Contents

    7.2. Schematic Diagram (Base Unit_Main) --------------20 7.3. Schematic Diagram (Base Unit_RF Part) ----------22 7.4. Schematic Diagram (Base Unit_Operation) -------23 7.5. Schematic Diagram (Cordless Handset) -----------24 7.6. Schematic Diagram (Charger Unit) ------------------26 8 Exploded View and Replacement Parts List -----------27 8.1. KX-TG1061CM--------------------------------------------27 8.2. KX-TGA106CM -------------------------------------------28...
  • Page 4: Safety Precautions

    KX-TG1061CM/KX-TGA106CM 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
  • Page 5: Specifications

    KX-TG1061CM/KX-TGA106CM 3 Specifications Note: • Design and specifications are subject to change without notice. Note for service: • Operation range: Up to 300 m outdoors, Up to 50 m indoors, depending on the condition. • Optional headset: RP-TCA86, RP-TCA94, RP-TCA95...
  • Page 6: Location Of Controls And Components

    KX-TG1061CM/KX-TGA106CM 4 Location of Controls and 4.1.2. Cordless Handset Components 4.1. Controls 4.1.1. Base Unit...
  • Page 7: Installation Instructions

    KX-TG1061CM/KX-TGA106CM 5 Installation Instructions 5.2. Battery 5.2.1. Battery Installation 5.1. Setting up 5.1.1. Connections Note: • The AC adaptor must remain connected at all times. (It is Note for service: normal for the adaptor to feel warm during use.) The battery strength may not be indicated correctly if the •...
  • Page 8: Battery Charge

    • The batteries need to be charged if the cordless handset beeps while you are engaged in a call or operating the answering system remotely. 5.2.4. Panasonic Ni-MH Battery Perfor- mance (supplied batteries) Note: • Actual battery performance depends on a combination of how often the handset is in use and how often it is not in use (standby).
  • Page 9: Operating Instructions

    KX-TG1061CM/KX-TGA106CM 6 Operating Instructions 6.1. Programmable settings You can customize the unit by programming the following features. To access the features, there are 2 methods: - scrolling through the display menus. - using the direct commands. • Direct command is the main method used in this service manual.
  • Page 10 KX-TG1061CM/KX-TGA106CM...
  • Page 11 KX-TG1061CM/KX-TGA106CM 6.1.2. Programming using the Direct Commands...
  • Page 12 KX-TG1061CM/KX-TGA106CM...
  • Page 13: Registering A Cordless Handset To A Base Unit

    KX-TG1061CM/KX-TGA106CM 6.2. Registering a Cordless Handset to a Base Unit 6.2.1. Deregistering a Cordless Handset...
  • Page 14: Copying Phonebook Entries

    KX-TG1061CM/KX-TGA106CM 6.3. Copying Phonebook Entries You can copy phonebook entries from the base unit to a cordless handset , and vice versa. Important: • Groups (including their names and ringer tones) are not copied. • You cannot make phonebook copy between cordless handsets directly.
  • Page 15: Error Messages

    KX-TG1061CM/KX-TGA106CM 6.5. Error Messages...
  • Page 16: Troubleshooting

    KX-TG1061CM/KX-TGA106CM 6.6. Troubleshooting If you still have difficulties after following the instructions in this section, disconnect the base unit’s AC adaptor, then reconnect the base unit’s AC adaptor. Remove the batteries from the cordless handset, and then insert the batteries into the cordless handset...
  • Page 17 KX-TG1061CM/KX-TGA106CM...
  • Page 18 KX-TG1061CM/KX-TGA106CM...
  • Page 19: Schematic Diagram

    KX-TG1061CM/KX-TGA106CM 7 Schematic Diagram 7.1. For Schematic Diagram 7.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology.
  • Page 20: Schematic Diagram (Base Unit_Main)

    KX-TG1061CM/KX-TGA106CM 7.2. Schematic Diagram (Base Unit_Main) +3.2V_PD VDD_flash_LCD CP_VOUT1 VDD4 R386 R387 TAM_WP *R542 270k TAM_WP *HOLD SPI_CLK SPI_DO *IC541 SPI_DI FLASH_CSn +3.2V_PD +1.8V L201 TAM_EN TAM_RESET L202 R202 TAM_RESET C218 TAM_EN C219 SPI2_CLK C220 SPI2_DI C221 SPI2_DO C222 SPI2_CLK...
  • Page 21 KX-TG1061CM/KX-TGA106CM CDL Tx (to Tel line) CDL Rx (from Tel line) SP_Phone Tx (to Tel line) SP_Phone Rx (from Tel line) (Corded) Handset Tx (to Tel line) (Corded) Handset Rx (from Tel line) Bell Bell (Power fail) CLIP LINE_DC Q111 +1.8V...
  • Page 22: Schematic Diagram (Base Unit_Rf Part)

    KX-TG1061CM/KX-TGA106CM 7.3. Schematic Diagram (Base Unit_RF Part) TP_ANT1 TP_ANT2 C863 C862 8.2n 3.3n W 0.15mm W 0.15mm L 21.5mm L 21.5mm C852 C853 4th layer 4th layer R808 C854 R809 ANT2 ANT1 W 0.15mm L 15.6mm 3rd layer C850 C851 C855 1.8mm 1st layer...
  • Page 23: Schematic Diagram (Base Unit_Operation)

    KX-TG1061CM/KX-TGA106CM 7.4. Schematic Diagram (Base Unit_Operation) LCD BACKLIGHT *R901 *LED901 *LED902 *R902 *LED903 *R903 CN901-7 SP-PHONE_LED *LED904 LED911 *R904 CN902-11 ANS_LED *LED912 CN902-14 *LED913 NEWMES_LED CN902-12 KEY5 CN902-13 KEY4 CN901-14 KEY3 CN901-4 KEY2 CN902-4 KEY1 CN901-3 KEY0 CN902-3 CN901-13 HOOK_DET...
  • Page 24: Schematic Diagram (Cordless Handset)

    KX-TG1061CM/KX-TGA106CM 7.5. Schematic Diagram (Cordless Handset) Charge Current BATTERY 5.6n BATT+ 1.8V BATTERY (MAX500mA) C150 BATTERY +1.8V 1.8V BATT- study to delete L8 X_CLK 3.0V 4.0V CP+3.0V CP+4.0V 3.9k CHG(+) CHARGE Terminal POWER K10u *C38 CHG(-) K10u +1.8V D10p D10p GND_0 K0.1u...
  • Page 25 KX-TG1061CM/KX-TGA106CM W 0.15mm L 20+/-2mm 3rd layer R807 RXON L801 C827 TP_ANT1 RX_RF C826 RF_RXn *C859 C803 1.5p DA801 RF_RXp W 0.125mm L 7.6mm CP+3.0V Gap 0.125mm W 0.15mm W 0.15mm 1st layer L 5.0mm L 5.0mm 1st layer 1st layer C172 K0.1u...
  • Page 26: Schematic Diagram (Charger Unit)

    KX-TG1061CM/KX-TGA106CM 7.6. Schematic Diagram (Charger Unit) R1 10 SCHEMATIC DIAGRAM (Charger Unit)
  • Page 27: Exploded View And Replacement Parts List

    STAND, WALLMOUNT ABS-HB PNHS1079Z SPACER, BATTERY COVER PNKK1027Z1 LID, BATTERY PNLC1008ZM CHARGER UNIT ASS'Y (RTL) Note: (*1) The rechargeable Ni-MH batery HHR-4DPA is available through sales route of Panasonic. (*2) Attach the SPACER (A9) to the exact location described above.
  • Page 28: Kx-Tga106Cm

    SPACER, BATTERY COVER A105 PNKK1027Z1 LID, BATTERY A106 PNLC1008ZM CHARGER UNIT ASS'Y (RTL) Note: (*1) Attach the SPACER (A104) to the exact location described above. (*2) The rechargeable Ni-MH batery HHR-4DPA is available through sales route of Panasonic. KXTG1061CM KXTGA106CM...