https://www.supplychimp.com
5-5-2 : Fine adjustment of fold position
If by test folds any folding misalignment is found after standard folding or non-standard folding is set,
fine adjustment of the fold position should be made according to the following procedure.
Using fine adjustment knob
Move the stopper using the stopper fine adjustment knob.
Caution: (In case the stopper fine adjustment knob is moved)
When the Test key is pressed, the machine will continue to fold,
and when the Start/Stop key is pressed, the machine will start to
fold after the stopper is returned to the previous position
[1] In case of "a"
Press the "+/-" key and move the stopper to the desired
position.
[2] In case of "b"
Press the "+/-" key and move the stopper to the desired
position.
[3] Press the "TEST" key to perform test folding.
If test folding is satisfactory, proceed to step [6].
If it is not satisfactory, adjust folding misalignment.
When readjustment is required, repeat the above
procedure [1] to [4].
[4] Press the "START/STOP" key to conduct
continuous folding
23