REFERENCES
5.2.4

Concatenation with Separate Code Transmission

If disabled, all concatenated codes are transmitted together as a single code
preceded and followed respectively by global headers and terminators (if working
with OM-1000 BT, only the cradle headers/terminators will be transmitted). When
enabling this parameter, all concatenated codes are transmitted separately and each
of them is preceded and followed by the defined headers and terminators (if working
with OM-1000 BT, only the cradle headers/terminators will be transmitted).
5.3

POWER SAVE

5.3.1

Power Off Timeout with BT Connection

When Lynx™ BT is radio connected to the system, after the desired timeout in
minutes, the Lynx™ BT batteries are disconnected and all power consumption
ceases. To restore power, press the trigger once. The reader will now be read to
read codes. Power-off does not effect configuration parameters.
5.3.2

Power Off Timeout with No BT Connection

When Lynx™ BT is not radio connected to the system, after the desired timeout in
minutes, the Lynx™ BT batteries are disconnected and all power consumption
ceases. To restore power, press the trigger once. The reader will now be read to
read codes. Power-off does not effect configuration parameters.
5.4

READING PARAMETERS

5.4.1

Safety Time

Safety time prevents the device from immediately decoding the same code more
than once. A timeout can be set up to 9.9 seconds before the decoder will accept the
same code. Reading is immediate if the code changes.
The safety time parameter is not applicable when all codes per scan is enabled or
when setting one read per cycle in hardware trigger operating mode.