Page 1
Please read the operating instructions carefully before use and keep for future reference. USAGE The Leister hot-air blower MISTRAL is suitable to build into machines or tools. It is designed for continuous operation. The tool offers process safety as a result of the integrated protective elements.
WARNING Danger to life when opening the tool, as live compo- nents and connections are exposed. Unplug the tool before opening it. Incorrect use of hot air blowers can cause fire and explosion hazard, especially near combustible materials and explosive gases. Do not touch the element housing and nozzle as long as they are hot since they can cause burns.
OPERATION Leister MISTRAL Description of tool 1. Power supply cord 5. Air slide 2. On/off switch 6. Air filter 3. Potentiometer for 7. Rubber stand temperature adjustment 8. Heater tube 4. Handle Assembling • Assembly must ensure that: – only cold air is supplied –...
Page 4
• The nozzles / reflectors are easily pushed onto the conical heater tube (8) and are then secured by fastening the screw on the clamp. • Only Leister nozzles / reflectors should be used.
• Check power supply cord (1) and plug for any possible electrical or mechanical damages. SERVICE AND REPAIRS • Repairs have to be carried out by authorised Leister Service Centres only. They guarantee a specialized and reliable repair service within 24 hours using original Leister spare parts.
Need help?
Do you have a question about the Mistral and is the answer not in the manual?