Download Print this page

Advertisement

Quick Links

Electronic special departement
Siedle Multi
Programming
instruction
HT 644-02
05.03
ex Vers. ES 04.5x

Advertisement

loading
Need help?

Need help?

Do you have a question about the HT 644-02 and is the answer not in the manual?

Questions and answers

Summary of Contents for SSS Siedle HT 644-02

  • Page 1 Electronic special departement Siedle Multi Programming instruction HT 644-02 05.03 ex Vers. ES 04.5x...
  • Page 2 HT 644-02 General information This Programming Instruction is valid for units from software version ES 4.5x . Older units from software version 4.16 onwards can be upgraded through replacing the EPROM at any time. Additionally, the D7 SMD-diode must be removed from the main printed- circuit-board.
  • Page 3 Outline of menus To commence programming Please dial throught the programming menu: Lift handset Enter "0000" Enter the password (8888) Programming menu < back Forward > Service menu Basic parameters with <OK> programming <OK> Set clock TLP call menu with <OK> with <OK>...
  • Page 4: Table Of Contents

    Programming- instruction Schedule of Contents Page 1 Basic parameters Setting-up the language (G, UK, F, NL, I) Unit address, group no., speech circuit enable, active/passive, video mode, compatibility, 2 Door-parallel-call menu Receiving a global or local door-parallel call 3 Collective-call menu Authorization to receive, authorization to send, group-collective call 4 Alarm-and-emergency-call menu Processing both alarm and emergency calls, fire alarms...
  • Page 5: Basic Parameters

    HT 644-02 1 Basic parameters menu Basic parameters programming <OK> Setting of general functions and options ⇒ open menue with , or Continue with 1.01 Unit address Log. address Each unit requires its own logic unit address. 1-500 _ _ 1 Up to a maximum of 4 units can be operated in parallel under the same address.
  • Page 6 Programming- instruction 1.03 Speech circuit 2 Speech circuit 2 inst. Y=1/N=0 The HT 644-.. unit is prepared for connecting two physical speech paths. If the second speech path is not wired, or if it is employed as a group speech path, it must be deactivated here. ⇒...
  • Page 7 HT 644-02 1.05 Video mode Video mode ? In combination with the VCO 640 video controller, a monitor which is allocated to the HT 644-.. unit can be directly connected by means of the integrated video-control interface, or by means of a porter’s-desk camera through output 12.
  • Page 8: Setting-Up The Language (G, Uk, F, Nl, I)

    Programming- instruction 1.07 Setting-up the language of the respective country Land/Country ? D=1 GB=2 F=3 NL=4 The text output in the display screen can be setup in 5 country languages at any time. G = 1 German UK = 2 English F = 3 French...
  • Page 9: Door-Parallel-Call Menu

    HT 644-02 2 Door-parallel-call menu TLP call menu The door-parallel call is a special, simultaneous door call to with <OK> subscribers with different unit addresses. A global door- parallel call to any number of subscribers is possible in Siedle Multi systems.
  • Page 10: Alarm-And-Emergency-Call Menu

    Programming- instruction 3 Collective-call menu Coll. call menu with <OK> In the Siedle Multi system, collective calls can be enabled and received by means of the HT 644-... unit. Two types of collective calls are possible: - A generic-collective call to all subscribers with authorization to receive.
  • Page 11 Up to 15 alarm and emergency calls can be received, menu with <OK> stored, and processed through the HT 644-02.. unit. They are shown both in the screen display and the LED 1. ⇒ Open menu with "1", confirm with or continue with 4.01 Receiving fire-alarms...
  • Page 12: Callback Menu

    Programming- instuction 4.05 Authorization to edit alarm calls Cancel alarm Adr1=1 all=0 Emergency calls can be cleared at the enabling place only. Alarm calls type 1 are cleared through both a call of the enabling subscriber and establishing a speech path. In this menu item, a decision is made whether each HT 644 unit (e.g.
  • Page 13 HT 644-02 5 Call back menu Call back menu Up to a maximum of 15 at all of non-answered calls can be with <OK< both stored and displayed as a callback request in the HT644 unit: - non-accepted calls (internal calls)
  • Page 14: Assigning Subscriber Numbers

    Programming- instruction 6 Assigning subscriber numbers Change call no. with <OK> Any subscriber number consisting of a maximum of four digits can be assigned to a unit address (1 - 500). This subscriber number is used for both calling the subscriber and showing in the display screen.
  • Page 15: Allocating Mfm

    HT 644-02 6 Assigning subscriber numbers, continued 6.04 Editing the table through the system Change table via system Y=1/N=0 The subscriber-number table can be transmitted through the system bus to all subscribers, in order to avoid manually entering with each subscriber. The "Initialization"...
  • Page 16 Programming- instruction 7 Allocating of MFM keys Allocate MFM with <OK> Up to a maximum of 3 MFM-611-10 units, with 10 programmable keys each, can be connected to a HT 644-.. unit. Subscriber calls as well as both control and switching functions can be freely allocated to the keys, in order to facilitate operating of the unit, especially regarding systems with complex functions, e.g.
  • Page 17 HT 644-02 7 Allocating MFM continued MFM ass. to 7.07 Allocating the "triggering fire alarm" function ** Fire alarm ** Our recommendation is: Allocate the function to a key through a double click: ∗) ∗) Function is not available if the collective-call menu is deactivated.
  • Page 18 Programming- instruction 14 Allocating MFM continued 7.17 Allocating the door release 2 function MFM ass. to Door release 2 Control key for activating the door release 2 in combination with a ETC 640-01. 7.18 Showing the current key allocation Display ass. of MFM button Actuate the corresponding MFM key (through single or double click).
  • Page 19 HT 644-02 ↓ Output 12 acti ↓ 8 Activating output 12 The HT 644-.. unit is furnished with a transistor OC- vate with <OK> switching-output which can be selected through both various actions or system states, e.g. the NS 541-0 unit can be directly connected as a secondary-signaling unit.
  • Page 20 Programming- Instruction 8 Activating output 12 continued 8.07 Activating the output through a switching function with switch fct. Y=1/N=0 Activating through a switching function to the HT 644-.. unit address for 3 sec. 8.08 Activating the output in the active/passive mode with active/passive Y=1/N=0 Activating when the switching exchange is in the active...
  • Page 21 HT 644-02 9 Switching LED 4 Switch LED 4 with <OK> The HT 644-.. unit is furnished with 4 LEDs, which signal various functions, respectively states, in addition to the display screen. The LEDs 1 - 3 have a fixed assignment.
  • Page 22 Programming- instruction 9 Switching LED 4, continued 9.05 Porter’s function is active ∗1) LED 4 Caretaker Y=1/N=0 If a porter’s group is activated, LED 4 is illuminated. Tip: If one of the 4 porter’s groups are activated, the LED is illuminated.
  • Page 23 HT 644-02 10 Enabling/disabling Keys or functions Keys / Functions . en/dis. with <OK> Various functions, especially the functions of the control keys on the HT 644 unit, as well as particular teleswitching functions, can be both individually enabled (released) and disabled (barred) for the subscriber.
  • Page 24 Programming- instruction 10 Releasing/barring Keys or functions, continued 10.04 Concierge (caretaker) groups ∗) Caretaker EN/DIS 1 2 -- -- Up to a maximum of 4 porter’s groups can be J=1/N=0 0 activated/deactivated through a HT 644-.. unit. ( key). For each HT, the authorization of each single concierge ∗) group can be individually enabled (released) or disabled (barred).
  • Page 25 HT 644-02 11 Setting the system clock Set clock The HT-644-.. unit has a clock function. Time indication can with <OK> be released, and the time is shown in the display screen. ⇒ Open menu with Set clock using sys..
  • Page 26 Programming- instruction 12 Service menue Service menue with <OK> This menue contains several functions for commissioning and troubleshouting. ⇒ Open menu with or continue with 12.01 Initializing Initialize Important status information of all units of the system is system with <OK> queried and, if required, saved in the particular units in the configuration memory (e.g.
  • Page 27 HT 644-02 12.02 Set default Set default with <OK> The HT 644-02 can be reseted to the delivery state. All individually configured features will be set to the default conditions. Tip: It´s recommended, to use this function, if the HT 644 has malfunctions, witch are not comprehensible or after installation an used, configured HT in a new system.
  • Page 28 – HT 644-02 Operating instruction – Siedle-Multi-Systemdokumentation and planning guide Please use the form "HT 644-02 programming list" for the documentation of the individually configuration and enclose this the system documentation. The agreed function of the HT 644-.. you can find at the functional description into our special tender, the unit address and group no.
  • Page 29 Electronic special department S. Siedle u. Söhne Telefon- und Telegraphenwerke Stiftung & Co Post box 1155 78113 Furtwangen Bregstraße 1 D 78120 Furtwangen Telefon ++49 7723/63-378 Telefax ++49 7723/4573...