Mitsubishi FR-A500 Series Instruction Manual page 73

Transistorized inverter: fr-a520-0.4k to 55k(-na) and fr-a540-0.4k to 55k(-na)(-ec)
Hide thumbs Also See for FR-A500 Series:
Table of Contents

Advertisement

Func-
Parameter
tion
Number
V/F4 (fourth frequency voltage)
107
(Note 1)
108
V/F5 (fifth frequency) (Note 1)
V/F5 (fifth frequency voltage)
109
(Note 1)
110
Third acceleration/deceleration time
111
Third deceleration time
112
Third torque boost (Note 1)
113
Third V/F (base frequency) (Note 1)
114
Third stall prevention operation current
Third stall prevention operation
115
frequency
116
Third output frequency detection
117
Station number
118
Communication speed
119
Stop bit length
120
Parity check presence/absence
121
Number of communication retries
122
Communication check time interval
123
Waiting time setting
124
CR LF presence/absence selection
128
PID action selection
129
PID proportional band
130
PID integral time
131
Upper limit
132
Lower limit
133
PID action set point for PU operation
134
PID differential time
Commercial power supply-inverter
135
switch-over sequence output terminal
selection
136
MC switch-over interlock time
137
Start waiting time
Commercial power supply-inverter
138
switch-over selection at alarm
occurrence
Automatic inverter-commercial power
139
supply switch-over frequency
Backlash acceleration stopping
140
frequency (Note 7)
Backlash acceleration stopping time
141
(Note 7)
Backlash deceleration stopping
142
frequency (Note 7)
Backlash deceleration stopping time
143
(Note 7)
144
Speed setting switch-over
145
Parameter for option (FR-PU04).
Stall prevention operation level at 0V
148
input
Stall prevention operation level at 10V
149
input
Name
Setting Range
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 3600 s/0 to 360 s,
0 to 3600 s/0 to 360 s,
0 to 30.0%, 9999
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz, 9999
48, 96, 192
0, 1 (data length 8)
10, 11 (data length 7)
0 to 10, 9999
0, 0.1 to 999.8 s, 9999
0 to 150ms, 9999
10, 11, 20, 21
0.1 to 1000%, 9999
0.1 to 3600 s, 9999
0 to 100%, 9999
0 to 100%, 9999
0.01 to 10.00 s, 9999
0 to 100.0 s
0 to 100.0 s
0 to 60.00Hz, 9999
0 to 400Hz
0 to 400Hz
0, 2, 4, 6, 8, 10, 102,
104, 106, 108, 110
60
Minimum
Setting
Increments
0.1V
0.01Hz
0.1V
0.1 s/0.01 s
9999
0.1 s/0.01 s
9999
0.1%
0.01Hz
0 to 200%
0.1%
0.01Hz
0.01Hz
0 to 31
1
1
1
0, 1, 2
1
1
0.1 s
1ms
0,1,2
1

0.1%
0.1 s
0.1%
0.1%
0 to 100%
0.01%
0.01 s
0, 1
1
0.1 s
0.1 s
0, 1
1
0.01Hz
0.01Hz
0 to 360 s
0.1 s
0.01Hz
0 to 360 s
0.1 s
1
0 to 200%
0.1%
0 to 200%
0.1%
PARAMETERS
Refer
Factory Setting
To
〈 〈 〈 〈 EC Version〉 〉 〉 〉
Page:
0
118
9999
118
0
118
9999
70
9999
70
9999
66
9999
68
150%
84
0
84
9999
83
0
119
192
119
1
119
2
119
1
119
0 〈9999〉
119
9999
119
1
119
10
130
100%
130
1 s
130
9999
130
9999
130
0%
130
9999
130
0
137
1.0 s
137
0.5 s
137
0
137
9999
137
1.00Hz
79
0.5 s
79
1.00Hz
79
0.5 s
79
4
82
150%
77
200%
77

Hide quick links: