5. External Wiring
5.1 Connecting to the RS-232 line
This section explains the standard method for connecting the RS-232 line.
1
6
2
7
3
8
4
9
5
1: QJ71C24N, QJ71C24
QJ71C24N-R2 QJ71C24-R2 : CH1/CH2 side
The following RS-232 interface connector is used for the module.
• DDK Ltd.
9-pin D-sub (female) screw type
17L-10090-27 (D9AC)(-FA)
Use one of the following as a connector shell for the connection cable of the
module side.
• DDK Ltd.
Plug, shell: 17JE-23090-02 (D8A)(-CG)
POINT
To connect the module with a modem/TA when using modem function, install wiring as
specified for the modem/TA.
Signal
Pin
number
abbreviation
1
CD
2
RD(RXD)
3
SD(TXD)
4
DTR(ER)
5
SG
6
DSR(DR)
7
RS(RTS)
8
CS(CTS)
9
RI(CI)
: CH1 side,
Signal name
Carrier detect
Receive data
Send data
Data terminal ready
Signal ground
Dataset ready
Request to send
Clear to send
Call Indicate
6
Signal direction
C24
External
( 1)