Mitsubishi PUHZ-SW75VHAPUHZ-SW100VHAPUHZ-SW100YHAPUHZ-SW120VHAPUHZ-SW120YHAPUHZ-SW75VHA-BSPUHZ-SW100VHA-BSPUHZ-SW100YHA-BSPUHZ-SW12 Service Manual page 97

Split-type, air to water heat pump
Table of Contents

Advertisement

OPERATING PROCEDURE
5. Removing the thermistor <2-phase pipe> (TH6)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Disconnect the connector TH7/6 (red), on the outdoor
controller circuit board in the electrical parts box.
(4) Loosen the fastener on the electrical parts box and unbind
the lead wires.
(5) Loosen the 2 wire clamps on top of the electrical parts box.
(6) Pull out the thermistor <2-phase pipe> (TH6) from the
sensor holder.
Note: When replacing thermistor <2-phase pipe> (TH6),
replace it together with thermistor <Ambient> (TH7)
since they are combined together.
Refer to procedure 6 below to remove thermistor
<Ambient>.
6. Removing the thermistor <Ambient> (TH7)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Disconnect the connector TH7/6(red) on the controller
circuit board in the electrical parts box.
(4) Loosen the fastener on the electrical parts box and unbind
the lead wires.
(5) Loosen the 2 wire clamps on top of the electrical parts box.
(See Photo 5)
(6) Pull out the thermistor <Ambient> (TH7) from the sensor
holder.
Note: When replacing thermistor <Ambient> (TH7),
replace it together with thermistor <2-phase pipe>
(TH6), since they are combined together.
Refer to procedure 5 above to remove thermistor
<2-phase pipe>.
7. Removing the thermistor <Liquid> (TH3),
thermistor <Discharge> (TH4) and
thermistor <Comp. surface> (TH34)
(1) Remove the service panel. (See Photo 1)
(2) Disconnect the connectors, TH3 (white) and TH4 (white),
TH34 (red) on the controller circuit board in the electrical
parts box.
(3) Loosen the cable strap for the lead wire in the front of the
electrical parts box.
(4) Loosen the fastener on the electrical parts box and unbind
the lead wires.
(5) Pull out the thermistor <Liquid> (TH3) and thermistor
<Discharge> (TH4) from the sensor holder.
[Removing the thermistor<Comp. surface> (TH34)]
(6) Remove the sound proof cover (upper) for compressor.
(7) Pull out the thermistor <Comp. surface> (TH34) from the
holder of the compressor shell.
OCH533D
Photo 5
Electrical parts box
Photo 6
Photo 7
Thermistor
<Comp. surface>
(TH34)
97
PHOTOS
Thermistor
<2-phase pipe>(TH6)
Clamp
Lead wire of thermistor
<Ambient> (TH7)
Sensor holder
Thermistor <Liquid> (TH3)
Motor for compressor
(MC)
Thermistor
<Discharge>
(TH4)

Advertisement

Table of Contents
loading