Instruction manual
General notes ....................................................22
1.
Safety advice......................................................23
2.
Intended purpose ..............................................24
3.
Product description ............................................25
3.1
Display and control elements ........................................25
3.2
Interfaces ......................................................................26
3.3
Voltage supply ..............................................................26
4.
Commissioning ..................................................27
5.
Operation ..........................................................28
5.1
Connect the probe ........................................................28
5.2
Switching the instrument on / off ..................................28
5.3
Switching the display light on / off ................................29
5.4
Performing settings ......................................................29
6.
Measuring ..........................................................33
7.
Care and maintenance ......................................36
8.
Questions and answers ......................................37
9.
Technical data ....................................................38
10. Accessories / Spare parts ..................................39
Visit us at www.TestEquipmentDepot.com
Temperature measuring instrument
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
testo 922
Content

Advertisement

Table of Contents
loading

Summary of Contents for TESTO 922

  • Page 1: Table Of Contents

    922 Temperature measuring instrument Instruction manual Content General notes ............22 Safety advice............23 Intended purpose ..........24 Product description ..........25 Display and control elements ........25 Interfaces ..............26 Voltage supply ..............26 Commissioning ..........27 Operation ............28 Connect the probe ............28 Switching the instrument on / off ........28 Switching the display light on / off ........29...
  • Page 2: General Notes

    General notes General notes This chapter provides important advice on using this documentation. The documentation contains information that must be applied if the product is to be used safely and efficiently. Please read this documentation through carefully and familiarise yourself with the operation of the product before putting it to use.
  • Page 3: Safety Advice

    Ensure correct disposal Take faulty rechargeable batteries/spent batteries to the collection points provided for them. Send the product back to Testo at the end of its useful life. We will ensure that it is disposed of in an environmentally friendly manner.
  • Page 4: Intended Purpose

    This chapter gives the areas of application for which the product is intended. Use the product only for those applications for which it was designed. Ask Testo if you are in any doubt. testo 922 is a compact measuring instrument for measuring temperatures.
  • Page 5: Product Description

    3. Product description Product description This chapter provides an overview of the components of the product and their functions. 3.1 Display and control elements Overview Infrared interface, probe socket(s) Display Control buttons Radio module compartment, battery compartment (rear) Key functions Functions Switch instrument on;...
  • Page 6: Interfaces

    “radio wave” segments shown indicates the strength of the signal) 3.2 Interfaces Infrared interface Measurement data can be sent to a Testo printer via the infrared interface on the head of the instrument. Sensor socket(s) Plug-in measuring probes can be connected via the probe socket(s) on the head of the instrument.
  • Page 7: Commissioning

    4. Commissioning Commissioning This chapter describes the steps required to commission the product. Removing t t he p p rotective f f ilm o o n t t he d d isplay: Pull the protective film off carefully. Inserting a a b b attery/rechargeable b b attery: To open the battery compartment on the rear of the instrument, push the lid of the battery compartment in the direction of the arrow and remove.
  • Page 8: Operation

    5. Operation Operation This chapter describes the steps that have to be executed frequently when using the product. 5.1 Connect the probe Plug-in probes Plug-in probes must be connected before the measuring instrument is switched on so that they are recognised by the instrument.
  • Page 9: Switching The Display Light On / Off

    5. Operation Switching t t he i i nstrument o o ff: Press and hold (for approx. 2s) until the display goes out 5.3 Switching the display light on / off Switching t t he d d isplay l l ight o o n / off: The instrument is switched on.
  • Page 10 5. Operation Each radio probe has a probe ID (RF ID). This consists of the last 3 digits of the serial no. and the position of the slide switch in the radio probe (H or L). Configuration mode is opened and RF ID and Auto are lit.
  • Page 11 5. Operation If further wireless probes are within reception range, the probe ID of a different wireless probe may be displayed. If necessary: switch off other wireless probes or remove from the reception range, and start automatic probe detection again with Press to change to the next function.
  • Page 12 5. Operation To s s et t t he d d ate/time: Configuration mode is opened, Year is lit. to set the current year and confirm with to set the other values for the month (Month), day (Day) and time (Time) and confirm each one with To s s et t t he u u nit o o f m m easurement: Configuration mode is opened, °C or °F flashes.
  • Page 13: Measuring

    6. Measuring Measuring This chapter describes the steps that are required to perform measurements with the product. The instrument is switched on and is in measurement view. Taking a a m m easurement: Put the probe in position and read off the readings. Changing t t he m m easurement c c hannel d d isplay: You can choose between a variety of display combinations, depending on which measurement...
  • Page 14 The readings shown on the display (current reading, recorded reading or max./min. reading) can be printed out. A Testo printer is required (accessory part). With the Max./Min. print function switched on, the maximum and minimum values are printed out as well as the current reading or recorded reading.
  • Page 15 The current readings of the measurement channels shown on the display can be printed out automatically at a fixed interval of time. A Testo printer is required (accessory part). The desired interval of time for cyclical printing has been set.
  • Page 16: Care And Maintenance

    7. Care and maintenance Care and maintenance This chapter describes the steps that help to maintain the functionality of the product and extend its service life. Cleaning t t he h h ousing: Clean the housing with a moist cloth (soap suds) if it is dirty.
  • Page 17: Questions And Answers

    O REGISTER THE RADIO PROBE Date/time are · Voltage supply was · Reset date and time. no longer correct interrupted for a longer time If we are unable to answer your question, please contact your dealer or Testo Customer Service.
  • Page 18: Technical Data

    9. Technical data Technical data Characteristic Value Parameters Temperature (°C/°F) Meas. range -50.0...+1000°C / -58.0...+1832.0°F Resolution 0.1°C / 0.1°F (-50.0...+199.9°C / - 58.0...+391.8°F) 1°C / 1°F (rest of range) Accuracy (±0.5°C+0.3% of reading) / (±0.9°F+0.3% of reading) (±1 Digit) (-40.0...+900°C / -40.0...+1652°F) (±0.7°C+0.5% of reading) / (±1.3°F+0.5% of reading) (rest of range) Sensor connections...
  • Page 19: Accessories / Spare Parts

    0602 1993 Robust air probe, TC type K 0602 1793 Miscellaneous TopSafe testo 922, protects from impact and dirt particles 0516 0222 Testo printer with IRDA and infrared interface, 1 roll thermal paper and 4 round cell batteries 0554 0547 Radio probes may only be used in countries in which they have been Type Approved (see application information of the radio probe).