Switch Positions And Rs232 Interface - Siemens 7XV5653-0BA00 Operating Instructions Manual

Two-channel binary signal transducer
Hide thumbs Also See for 7XV5653-0BA00:
Table of Contents

Advertisement

s

1.4.2 Switch positions and RS232 interface

The DIP switches can be operated from outside.
Position of the DIP-Schalter:
FO receiver
ST input •
FO transmitter
ST output •
ON OFF
8
1
7
S1
2
6
5
4
3
2
X1
1
OFF ON
Fig. 4: Positions of the switches
Page 28 of 40
2-channel Binary Signal Transducer
View from the front
S2
s
Pin
Description
1
-
2
Receive data
3
Transmit data
4
-
5
Signal ground
6
-
7
Signal ground
8
Active interface
selection
9
-
Table 5: RS232 interface, 9-pole sub-D socket
Explanation
Switch
Not connected
Factory setting is
FO connection
DIP switch (S1, S2)
Switch
Position
1
Open
Closed
2
Open
Closed
Table 6: S1, DIP switch (2)
Bold type = factory setting
A 01/13
A 01/13
A b b r e v i a t i o n
-
RxD
T x D
-
G N D
-
G N D
Bridge
-
Meaning
FO connection active
RS232 connection
active
Meaning
= off
Light off in idle state: FO receiving
= on
Light on in idle state: FO receiving
= off
Light off in idle state: FO
= on
transmitting
Light on in idle state: FO transmitting
2-channel Binary Signal Transducer
Direction as
D T E
No connection
In ←
O u t →
No connection
-
-
-
I n p u t
-
Remark
Pin 8 open
Bridge pin 8 – 7
At the converter input
Page 29 of 40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents