System Status Indicators In A Splitter - Martin Exterior 50 User Manual

Ip68
Table of Contents

Advertisement

System status indicators in a Splitter

See Figure 34. Two indicator LEDs inside a Splitter give information about
system status:
• Link flashes green: indicates data transmission at one or both of the
DMX data outputs.
• Voltage lights constant yellow: indicates that the DC power received is
outside the 20-40 V acceptable range.
• Voltage flashes yellow: identifies the DC power voltage received.
- Long flashes indicate multiples of 10
- Short flashes indicate single digit
Example: Voltage LED gives two long flashes and nine short flashes –
DC voltage is 29 V.
For access to the indicator LEDs, follow the instructions in "Internal
access to a Splitter" on page 44. If IP68 sealing compound has been
injected, the LEDs should still be visible through the gel sealant.
Figure 34: Status indicator LEDs in Splitter
Checking and monitoring the installation