R-1330/NS-BP400
4. AD DATA CHECK
This menu is used to display the A/D conversion
value of the main microprocessor which detects
panel keys of this unit and protection functions in
using the sub-menu.
4-1. PRT1 PS1
(Power supply voltage protection detection)
Power supply voltage protection value
(Normal value PS1: 107 to 133)
PS1: Detects +12A, -12A, +5I, +29V, +12MVOL
and AC (D202-203 of the MAIN P.C.B.).
*
If PS1 is out of the normal value range, the
protection function works to turn off the
power.
(Reference voltage: 5.0V=255)
4-2. PRT2 DAMP
(Power supply voltage of digital amplifier
protection detection)
Power supply voltage protection value
(Normal value DAMP: 65 to 121)
DAMP: Detects +12DAMP and -5D.
*
If DAMP is out of the normal value range,
the protection function works to turn off the
power.
(Reference voltage: 5.0V=255)
4-3. THM
(Temperature detection)
Temperature protection value
(Normal value THM: 10 to 85)
THM: Detects D202 of the MAIN P.C.B..
(Reference voltage: 5.0V=255)
30
4. AD DATA CHECK
本機パネルキー、プロテクションなどを検出してい
るメインマイコンの A/D 変換の値を、サブメニュー
で表示します。
4-1. PRT1 PS1
(電源電圧プロテクションの検出)
プロテクションの値
(正常値 PS1:107 ∼ 133)
PS1: +12A、-12A、+5I、+29V、+12MVOL、
※ PS1 は正常値を外れるとプロテクションが働
(基準電圧:5.0V=255)
4 1 . P S 1 : 1 2 2
4-2. PRT2 DAMP
(デジタルアンプ用電源電圧プロテクションの検
出)
プロテクションの値
(正常値 DAMP:65 ∼ 121)
DAMP: +12DAMP、-5D を検出しています。
※ DAMP は正常値を外れるとプロテクションが
(基準電圧:5.0V=255)
4 2 . D A M P : 9 4
4-3. THM
(温度検出)
温度検出値
(正常値 THM:10 ∼ 85)
THM: MAIN P.C.B. の D202 を検出しています。
(基準電圧:5.0V=255)
4 3 . T H M : 4 8
AC(MAIN P.C.B. の D202、D203)を検出
しています。
き、電源が切れます。
働き、電源が切れます。