Communications Subcommands - Omron V680-CA1D User Manual

V680 series heat-resistive rfid system
Table of Contents

Advertisement

Section 4
Reading from/Writing to Tags

Communications Subcommands

COMMAND PROCESSING ABORT (AA)
Aborts processing of an AUTO command being executed and returns to the command standby status.
Command
Controller No.
×
@
3
Response
Controller No.
×
@
3
Name
End code
• Example
Aborting AUTO command processing during execution in Controller No. 2.
Command
Controller No.
0
@
3
Response
Controller No.
@
0
3
Heat-resistive RFID System
72
User's Manual
Command code
FCS
×
×
×
A
A
2
2
Command code
End code
×
0
0
A
A
2
2
Indicates the execution result for the command.
14: AUTO command processing not executed.
75: Aborted as a result of Tag not being in range.
Command code
FCS
3
6
2
A
A
2
2
Command code
End code
A
A
7
5
2
2
2
Terminator
*
CR
2
FCS
Terminator
×
×
*
CR
2
2
Details
Terminator
*
CR
2
FCS
Terminator
*
4
0
CR
2
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680-ca2dV680-h01V680-d1kp58ht