Siemens S7-1200 TELECONTROL Operating Instructions Manual page 26

Hide thumbs Also See for S7-1200 TELECONTROL:
Table of Contents

Advertisement

LEDs and connectors
2.2 LEDs
DIAG
NETWORK
(red / green)
(red / green)
flashing
green
flashing
green
TeleServiceconnection
-
-
-
Quality of the mobile wireless connection
-
-
-
-
-
-
-
-
-
flashing red
Loading firmware
flashing
green
flashing red
26
CONNECT
SIGNAL
QUALITY
(green)
(yellow /
green)
-
-
-
-
-
-
-
-
-
-
-
TELE-
Meaning
SERVICE
(green)
-
Telecontrol configuration exists, partner not
reachable, CPU in RUN mode
-
Telecontrol configuration exists, partner not
reachable, CPU in STOP mode
TeleService connection established
No TeleService connection established
-
Good network (-73 ... ≥ -51 dBm)
-
Medium strength network (-89 ... -74 dBm)
-
Weak network (-109 ... -90 dBm)
-
No network (≤ -110 dBm)
-
Missing external power supply
Loading firmware.
The "DIAG" LED flashes alternating red and
green.
Firmware was successfully loaded.
Error loading firmware
or
Internal error of the CP; remedy: Power
OFF → ON
Operating Instructions, 10/2016, C79000-G8976-C311-02
CP 1242-7 GPRS V2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S7-1200 - telecontrolCp 1242-7 gprs v2

Table of Contents