Troubleshooting

No gas to burner on lighting
Fire does not stay lit when knob
released
Fireplace shuts off during use
Fan does not work
Gas odor even when control knob
is in OFF position
Slight smoke or odor during initial
operation
Problem
Remedy
Check gas supply, regulator, solenoid
Check that knob is exactly on LOW which
is 9 o'clock when pressed in.
Orifice is clogged due to dirt build up or
material in new hose installation.
Depress knob, light burner and almost
close door. Release knob and then CLOSE
COMBUSTION CHAMBER DOOR
Check that the door seal is good
Check that the internal exhaust pipe is
installed correctly
No gas supply – check gas pressure
Blockage of the air intake – check the vent
pipe for any object, including water that
may block the intake.
Check power supply (12 V DC)
Check connection of wires
Check proper functioning of switch
Replace fan
1. Gas leak. See Warning.
Locate and correct all leaks
2. Check and, if required, replace the
control valve. If operation is attempted
with high pressure gas, the valve could
fail.
This is a normal event, caused by burning
off of residues from the manufacturing
process. Smoke and odor should stop after
a few hours of operation