GE JT3500DF3WW Installation Instructions Manual page 2

27 inch & 30 inch electric built-ln wall ovens
Table of Contents

Advertisement

Available languages

Available languages

CUTOUT
FOR SINGLE OVENS IN WALL
CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than sA" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
H
These ovens
are Not
approved for
stockoble
installations.
E _--T>
Opening
Between Inside
Walls Kust be
at Least 28-1/2"
(72.4 cm} Wide
Junction
BOX
Location
(junction
in adjacent
cabinet}
22" (55.9
D..= _
cm) _qin.to
Bottom of
Junction
BOX
.--L';'-
. - _
Cutout Depth
"1"-_--_
_____23
1/2"
(59.7 cm} klin.
Note: Allow
1/4" 10.64 cm}
clearances
from side
edges of oven
door.
_--._
B =====_
t
F
C
G
lr
t
Install
two
ovens
in separate
cutouts
Center Line
Center Line
305" (77.5 cm}
I
30" models
I<
-i
27" (6858 cm)
I
27" models
observe all
observe all
dimensions and
dimensions
and
requirements
requirements
"""""'_
['_=="
2" {5.1 cm) IVlin.
Dimension
Dimension Description
27" Single Oven
30" Single Oven
A
Cabinet Width
27" (68.6 cm)
30" (76.2 cm)
B
Cutout Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
Cutout
Height
25Y/' (64.1 cm) max.
27%" (70.2 cm) min.
28½" (71.4 cm) max,
i" (2.5 cm)
23" (50.8 cm) min.
1" (2.5 cm) min.
1" (2.5 cm) min.
Recommended
Cutout Location
from Floor
52-1/2" (826 cm)
I1
A -d
28%" (72,7 cm) max.
2F//' (69.2 cm) min.
27_A" (69.4 cm) max,
1VS' (1.75 cm)
23" (53.3 cm) min.
C
D
E
Overlap of Oven Over
Side Edges of Cutout
Clearance to
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
Overlap of Oven
Top of Cutout
Overlap of Oven
Bottom of Cutout
1" (2.5 cm) min.
flY/'
(3,2 cm) for PT9050,
ZETIS and ZET1P)
I_A " (3.2 cm)
H
Junction Box Location
83//' (22.2 cm) max.
9½" (24.1 cm) max.
right side only
right side only
121BICUTOUT
FOR SINGLE OVENS-
UNDER COUNTER
NOTE: These ovens are only approved to be installed under the specific models as labeled on the unit.
Gas or Electric
Cooktops
May Be Installed
Over This Oven,
See Cooktop
Installation
Instructions
for Cutout
Size,
See Label
on Top of Oven
for Approved
Models,
240V/208V
Junction
Box
Location
(junction
box may be
in adjacent
cabinet)
25" (63.5 cm)
Gas and Electrical
Connections
for Gas Cooktop
Must be Located
in an Adjacent
Accessible
Location
to the Right
MUST SUPPORT
220 ibm (9g kg) FOR SINGLE
OVENS
MUST SUPPORT
400 Ibm (181 kg) FOR DOUBLE
OVENS
Side-by-Side Installations
Install two ovens in separate cutouts.
Center Line
Center Line
305" (775 cm} 50" models
b2T'
(68.58 cm} 27" models
JL
Cutout - observe
Cutout - observe
all dimensions and
all dimensions and
requirements,
requirements.
==="t_1
_
2" (51 cm} Min
NOTE: One cooktop may be centered over either oven in
the side-by-side installation.
22" (55.9 cm) Min,
36" (91.4 crn)
Above
Support
Platform
Countertop
Height
_1
4" (10.2 Cm)
_
Toekick
Dimension
A
B
C
D
E
F
Dimension
Description
Cabinet
Width
Cutout
Height
Unit
Overlap
Top
Unit
Overlap
Bottom
Unit Overlap
Side Edges
Junction
Box Location
27" Single Oven
25" (63.5 cm) min.
25_//' (64.1 cm) max.
275_ " (70.2 cm) rain.
28½" (71.4 cm) max.
i" (2.5 cm)
1" (2.5 cm)
1" (2.5 cm)
8_//' (22.2 cm) max.
right side only
30" Single
Oven
28½" (72.4 cm) min.
28%" (72.7 cm) max.
27_A" (69.2 cm) min.
27YS' (69.4 cm) max.
1" 12.5 cm)
(1V/' (3.2 cm) for PT90S0
ZET1S and ZET1P)
I_A " (3.2 cm)
1VS' 11.75 cm)
9½" (24.1 cm) max.
right side only
Continue
to Section
4.

Advertisement

Table of Contents