GE JT3500DF3WW Installation Instructions Manual page 3

27 inch & 30 inch electric built-ln wall ovens
Table of Contents

Advertisement

Available languages

Available languages

CUTOUT
FOR DOUBLE OVENS 12THERMAL OVENS1
NOTE: If the cabinet
does not have a front
frame
and the sides are less than
sA" (1.9 cm)
both sides equally
to establish
the cutout
i=ldth.
_AL,I
_ "1
Junction
_
B
""""""'_
,
.
Box
r
,,
l
Location
'
I
(junction
',
I
/
boxmay
!
I
/beloca/ed
..........
'._
I
--in
adjacent
cabinet}
E _
J
. - " "
Cu{ou/Depth
:--_'-_
23-i/2"
_(597
crn}
Min
t
F
D
.=.._ ,,l==
G
t
hick, shim
k--
Dim.
Description
27" Double Oven
30" Double
Oven with
30" Double
Oven
Pedestal
without
Pedestal
A
Cabinet
Width
27" (68.6 cm)
30" (76.2 cm)
30" (76.2 cm)
B
Cutout
Width
25" (63.5 cm) min.
28½" (72.4 cm) min.
28½" (72.4 cm) min.
25½" (64.1 cm) max.
28%" (72.7 cm) max.
28%" (72.7 cm) max.
C
Cutout
Height
491¼d ' (126.2 co) min.
511__d' (131.6 cm) min.
50 l/j, (127.64cm)
50½" (127.3 cm) max.
51_d
' (131.9 cm) max.
D
Overlap
of Oven
1" (2.5 co)
_/'
(1.75 cm)
_/'
(1.75 cm)
Over Side Edges
of Cutout
E
Clearance to
23" (50.8 cm) min.
23" (53.3 cm) min.
23" (53.3 cm) min.
Adjacent Corners,
Drawers, Wails, etc.,
When Door Is Open
F
Overlap
of Oven
1" (2.5 co) min.
1" (2.5 cm) min.
1" (2.5 cm) min.
Top of Cutout
(1½" {3.2 co) for PT9550,
(1½" {3.2 co) for PT9550,
ZET2S and ZET2P)
ZET2S and ZET2P)
G
Overlap
of Oven
1" (2.5 co) min.
1¼" (3.2 cm)
1¼" (3.2 cm)
Bottom of Cutout
H
`junction
Box
8¾" (22.2 cm) max.
9½" (24.1 cm) max.
9½" (24.1 cm) max.
Location
right side only
right side only
right side only
,j
Height
to Bottom
44" (111.8 cm)
47" (119.4 cm)
47" (119.4 cm)
of.Junction
Do×
K
Recommended
13½" (33.7 cm)
12" (30.5 co)
12" (30.5 cm)
Cutout
Locution
from
Floor
Continue
to Section
3,
CUTOUT
FOR INSTALLATION
OVER A WARMING
DRAWER
NOTE: Install the over] only with specific
models
listed on the label
located
on top of the over].
NOTE: Additional
clearances
between
cutouts
may be required.
Check to be sure the oven supports
above
the Warming
Drawer
location
do not obstruct
the required
interior
depth
and height.
When
installing
a Warming
Drawer
below
a single or double
oven, a separate
120V, 60 HZ, properly
grounded
receptacle
must be installed.
Refer to installation
instructions
packed
with
the Warming
Drawer
for specific
installation
requirements.
Anti-Tip
Block Against
Rear Wall Per Warming
Drawer Requirement
T
2" (5.1 era)
Min.
Per Warming
Drawer
Requirement
Continue
to Section
3 for DWO with
Pedestal.
Otherwise,
continue
to Section
4.
J 31-10979
J 0714 GE

Advertisement

Table of Contents
loading

Table of Contents