F8914
Page
Total:26

Advertisement

Table of Contents
loading

Summary of Contents for Four-Faith F8914-N

  • Page 1 The user manual is suitable for the following model: Model Product Type F8914-N ZigBee Terminal F8914-E ZigBee Terminal(with PA) Xiamen Four-Faith Communication Technology Co., Ltd. Add:J1-J3,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China Zip Code: 361008 Tel: +86 592-5907276 Fax: +86 592-5912735 http://en.four-faith.com Email: nick@four-faith.com Tel:+0086-592-5907276/5907277...
  • Page 2 2014-09-20 V1.14 Add appendix Update Power Consumption 2015.05.25 V1.15 Cm.chen Delete AT mode and API mode description 2015.11.12 V1.16 Email: nick@four-faith.com Tel:+0086-592-5907276/5907277 Web: en.four-faith.com Add: 3rd Floor, No.44 Guan Ri Road, Software Park, Xiamen, China...
  • Page 3: Copyright Notice

    Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual (all files shall be not revised, and the copyright and other proprietorship notice shall be reserved) are welcome.
  • Page 4 User Manual F8914 Email: nick@four-faith.com Tel:+0086-592-5907276/5907277 Web: en.four-faith.com Add: 3rd Floor, No.44 Guan Ri Road, Software Park, Xiamen, China...
  • Page 5: Table Of Contents

    Appendix........................... 24 A1 Notes..........................24 A1.1 Serial port’s frame interval................24 A1.2 About the factory setting.................. 24 A1.3 About the network parameters................. 24 A1.4 Sleep mode....................... 24 Email: nick@four-faith.com Tel:+0086-592-5907276/5907277 Web: en.four-faith.com Add: 3rd Floor, No.44 Guan Ri Road, Software Park, Xiamen, China...
  • Page 6 A1.7 Transmit Power....................25 A2 FAQ..........................26 FAQ1:Configure parameters fail................26 FAQ2:With right parameters,but add network fail..........26 FAQ3:In network,but send data fail..............26 FAQ4:Can not enter sleep..................26 Email: nick@four-faith.com Tel:+0086-592-5907276/5907277 Web: en.four-faith.com Add: 3rd Floor, No.44 Guan Ri Road, Software Park, Xiamen, China...
  • Page 7: Chapter 1 Brief Introduction Of Product

    User Manual Chapter 1 Brief Introduction of Product 1.1 General F8914 is a kind of data terminal device that provides data transfer function by ZigBee network. It adopts high-powered industrial CPU and embedded real time operating system. It supports RS232, RS485 (or RS422) and ZigBee port that can conveniently and transparently connect one device to a cellular network, allowing you to connect to your existing serial and ZigBee devices with only basic configuration.
  • Page 8: Working Principle

    User Manual Standard and Convenience  Adopt terminal block interface, convenient for industrial application  Support standard RS232 and RS485(or RS422) port that can connect to serial devices directly  TTL logic level RS232 interface can be customized  Support intellectual mode, enter into communication state automatically when powered ...
  • Page 9: Specifications

    User Manual 1.4 Specifications ZigBee Specification Item Content ZigBee Module Industrial ZigBee module Standard and Band IEEE 802.15.4 ISM 2.4 GHz Indoor/Urban Range 90m(With PA) Outdoor/RF Line-of-Sight Range 500m 2000m(With PA) 2.82mw (+4.5dBm) Transmit Power 100 mw (+20dBm) (With PA) Bandwidth 250Kbps -97dBm...
  • Page 10 Content Standard Power DC 12V/0.5A Power Range DC 5~35V Power Consumption Working States Power Consumption RX Mode ≤15mA/12V@4.5dBm TX Mode ≤20mA/12V@4.5dBm F8914-N Timing wake up ≤3.5mA/12V@4.5dBm Deep Sleep ≤2.5mA/12V@4.5dBm RX Mode ≤15mA/12V@21dBm TX Mode ≤80mA/12V@21dBm F8914-E Timing wake up ≤4.5mA/12V@21dBm Deep Sleep ≤3.5mA/12V@21dBm...
  • Page 11: Chapter 2 Installation Introduction

    RS232 data cable optional RS485 data cable optional Manual CD Certification card Maintenance card Table 2-1 Encasement List Xiamen Four-Faith Communication Technology Co.,Ltd. Page 11 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 12: Installation And Cable Connection

    2, Keep the antennas visual. 3, Minimize obstructions between the antennas. 4, Reduce the extension cords of the antenna. The performance of different antenna installation types, as the figure 2-2. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 12 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com...
  • Page 13 User Manual F8914 antenna mode Figure 2-2 Installation Xiamen Four-Faith Communication Technology Co.,Ltd. Page 13 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 14 Adapter(Rating Output 12VDC/0.5A) : Cable Color Power Output Polarity Black &White Alternate Anode Black Cathode Xiamen Four-Faith Communication Technology Co.,Ltd. Page 14 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 15 Block Interface Block Interface (DB9M) + Anode + Anode - Cathode - Cathode Communication Interface: RS232 Communication Interface: RS485 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 15 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 16: Power

    No data Online F8914 has logged on network F8914 hasn’t logged on network FLASH Joining or establishing a network Xiamen Four-Faith Communication Technology Co.,Ltd. Page 16 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 17: Chapter 3 Zigbee Description

    3.1.3 End Device An end-device has no specific responsibility for maintaining the network infrastructure, so it can sleep and wake up as it chooses. Thus it can be a battery-powered node. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 17 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China...
  • Page 18: Zigbee Network Description

    Pan ID.This Pan ID is used on every device in a same ZigBee network. Four-Faith ZigBee product can pre-configure a Pan ID and randomly select a Pan ID. In AT command mode ,we send “AT+PID=N”,(N=0-65531),if PID=65535 ,it will randomly select a Pan 3.2.4 Node address...
  • Page 19: Chapter 4 Configuration

    Please reference to Appendix in detail).During this time, the network not works,and the serial’s baud rate is 115200,no parity, 1 stop bit. Send the 3-character command sequence“+++”twice through serial port.Then it goes into AT command configuration. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 19 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China...
  • Page 20: Run The Configure Tool: Zigbeeconfigure.exe

    The configure tool window contains “Com setting”, “Device information” and “Zigbee parameters setting”. Press button can show or hide the log information. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 20 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 21: Modes Of Operation

    (data is communicated in frames in a defined order). The API specifies how commands, command responses and module status messages are sent and received from the module using a UART Data Frame. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 21 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China...
  • Page 22 2.Every configure item is set, it should send save command.Network param(PAN ID,Physical Channel ,node address or device type changed),sleep param and serial param change should re-power device. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 22 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com...
  • Page 23: Device Sleep Mode Configuration Description

    Configuration conditions (1) Hardware :Operate on IO1’s level. (2) Software : Device should be configured as end device or router and Deep Sleep. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 23 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com...
  • Page 24: Appendix

    On API work mode,the serial data should be avoid of 0xFE data. On transparent work mode, the serial data should be avoid “+++” and “===” string. A1.6 Power on timing Xiamen Four-Faith Communication Technology Co.,Ltd. Page 24 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China...
  • Page 25: A1.7 Transmit Power

    A1.7 Transmit Power Keep more than 20cm distance between two ZigBee device, when tested or in practical application Xiamen Four-Faith Communication Technology Co.,Ltd. Page 25 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.four-faith.com...
  • Page 26: A2 Faq

    2. On deep sleep mode. Please check the sleep control(SLEP_REQ) pin’s wire splice is OK and the control level is OK(high level make device sleep, otherwise awake) Xiamen Four-Faith Communication Technology Co.,Ltd. Page 26 of 26 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China...