FAULT DISPLAY
The FAULT is indicated by an 'F' on the left hand side digit and the fault number in the 'XX' format on
the right.
AUTOTEST ACTIVATION
The autotest function starts with the appliance off.
If there is a Last Fault in the memory, the appliance shows it immediately for 20 seconds, after which
the Autotest sequence commences.
The Last Fault only cancels at the end of the Autotest sequence. If the autotest is interrupted, the Last
Fault is presented again when the procedure is restarted.
On completion of the autotest, a long beep sounds and the appliance turns OFF again. The Last Fault
transfers to rolling visible memory only via the Cooling Doctor diagnostic tool.
AUTOTEST ACTIVATION
ACTIVATION
Long press of the Super Freeze key for 6
seconds (or Super Cool on single door fridges).
AUTOTEST SEQUENCE
Step
Duration
1
5 seconds
2
1 second
3
4 seconds
4
245 seconds
5
245 seconds
6
Service Manual UK
-
-
-
Action
FG Light
Pause
OFF
Probe check
OFF
Pause
OFF
FG fan ON
ON
FG fan ON
Blinking
End of Autotest
12 of 29
DISPLAY
All LEDs light up for 2 seconds.
The Last Fault is shown (where present) for
20 seconds.
All LEDs light up for remaining duration of
the autotest.
If the probe control is OK, it skips to step 3.
If there are probe faults (KO), it skips to
step 5.
After this test, it skips to step 6