10.2 Error detection for CD/ Changer block
TOP PREVIOUS NEXT
No. Error
1
REST SW detection error
2
CD tray opens automatically
3
Does not startup when [PLAY]button is pressed
4
Transmission error between CDservo LSI and micon
5
Startup fails even when youinsert CD or the selected disc tray
does not open
6
Cannot insert CD
7
Cannot eject CD
8
The CD tray closes
TOP PREVIOUS NEXT
file:///D|/Documentos/Manolo/Service/Panasonic/Manuales/Audio/SA-AK500P_SA-AK500PC/SVC/s1002000000.html[17/03/2009 01:02:21 p.m.]
ErrorDisplay Problem condition
F15
CD does not function.This error occurs when the Optical Pick Up REST SW (S701) is not
detected within the specified time (about 8 seconds)
F16
CLAMP switch (S4) NG (Check & Replace)
F17
BOTTOM switch (S5) NG (Check & Replace)
F26
CD does not function.This error occurs when the POWER is ON for the CD block and an error is
detected after the transmission has started.
F27
Tray 1 detect switch or Tray 2 detect switch NG (Check & Replace)
F28
Tray 1 detect switch NG (Check & Replace)
F29
Check if disc is stuck. Tray 2 detect switch NG (Confirm & Replace)
H15
CD disc tray detect switch NG (S3) (Check & Replace)