Preparing for installation
Preparing for installation
1. Align the supplied installation tem-
plate on the wall.
2. Drill 7 10 mm holes and insert the
rawl plugs supplied.
3. Fit wall mounting bracket with screws
supplied.
Preparing the connections
!
Please note
To prevent equipment damage,
install all pipework free of load
and torque stresses.
1. Prepare the water connections. Flush
the heating system.
2. Prepare the gas connection.
3. Prepare the electrical connections.
Observe applicable IEEE standards.
■ A 1.5 m power cable is fitted in the
delivered condition.
■ A 1.5 m connecting cable for the
circulation pump is provided sepa-
rately.
■ Accessory cables:
NYM-O two-core min. 0.5 mm