Flame Operation - Warmington Traditional Fire - Gas 1000 Installation Instructions Manual

Traditional brick built open gas fire & gas burner
Table of Contents

Advertisement

OPERATION OF YOUR REMOTE CONTROLED EG/SG GAS BURNER (SIT 845 valve) ELECTRONIC
AS SHOWN FROM THE FRONT OF THE BURNER
This Control Panel is located on the bottom left hand side of your Warmington decorative gas fire.
Press and release the power button. This will start the electronic spark and the power LED will be on
permanently . The pilot will ignite first and once this is on, it will ignite the main burner. Pressing and
releasing the power button again will switch off the appliance.
When the appliance is turned on again, the gas fire will resume the previous flame and fan settings,
unless the appliance was switched off due to power failure. In the circumstance of a power failure the
Remote Control System will return to the default settings which is a low flame and the fan turned off.
If the gas fails to light, the appliance it will go into lock out mode, after trying to ignite for 1 minute
(approx.). In lock out mode the power LED will remain illuminated. To start the appliance again, press
and release the power button twice after the gas supply resumes.

FLAME OPERATION

Press and hold the + button to increase the main burner flame.
Press and hold the - button to decrease the main Burner Flame.
By holding the + or - Flame Button for up to 10-15 seconds, this will increase or decrease the
main burner flame to it's max or min.
22
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm.............Copyright ©