transmitted signal to not be fully absorbed by the load. This causes a portion of the signal to
be reflected back into the transmission line as noise. If the source impedance, transmission
line impedance, and load impedance are all equal, the reflections (noise) are eliminated.
Termination resistors increase the load current and sometimes change the bias requirements
and increase the complexity of the system.

4.5.5 Connecting serial Baldor HMI Operator Panels

Serial Baldor HMI Operator Panels use a 15-pin male D-type connector (marked PLC
PORT), but the NextMove e100 Serial connector uses a 9-pin male D-type connector. The
NextMove e100 may be connected as shown in Figure 24:
Alternatively, the Baldor HMI panel may be connected using RS485/422, as shown in
Figure 25:
4-24 Input / Output
Baldor HMI
PLC PORT
Twisted pair
RXD 2
TXD 3
GND 5
1
Figure 24: RS232 cable wiring
Baldor HMI
PLC PORT
Twisted pair
TXA 14
TXB 6
RXA 15
RXB 7
GND 5
1
Figure 25: RS485/422 cable wiring
NextMove e100
Serial Port
7 RTS
8 CTS
3 TXD
2 RXD
5 GND
NextMove e100
Serial Port
8 RXA
2 RXB
7 TXA
3 TXB
5 GND
MN1941WEN