Factory Preset; Ad Data Check - Yamaha NS-BP300 Service Manual

Micro component system receiver/speaker package
Hide thumbs Also See for NS-BP300:
Table of Contents

Advertisement

3. FACTORY PRESET

This menu is used to reserve/inhibit initialization of the back-up IC.
Select this menu and press the "PRESET
3 0 . P R T I N H
3 0 . P R T R S R V

4. AD DATA CHECK

This menu is used to display the A/D conversion value of the microprocessor which detects panel keys of this unit and
protection functions by using the sub-menu. (Reference voltage: 5.0 V = 1023)
4-1. PS1
Power supply voltage protection 1 detection
Voltage detects: ±B, +VP and +9T.
Normal value:
366 to 687
(Reference voltage: 5.0 V = 1023)
*
If PS1 becomes out of the normal value range, the protection function works to turn off the power.
4-2. PS2
Power supply voltage protection 2 detection
Voltage detects: +9T, ±7V and +3.3DAB (A, B models).
Normal value:
366 to 679
(Reference voltage: 5.0 V = 1023)
*
If PS2 becomes out of the normal value range, the protection function works to turn off the power.
4-3. DC
Power amplifier DC (DC voltage) output detection
Normal value:
0 to 500
(Reference voltage: 5.0 V = 1023)
*
If DC becomes out of the normal value range, the protection function works to turn off the power.
" (Up) key to change display.
PRESET INHIBIT (Initialization inhibited)
Back-up IC initialization is not executed.
Select this sub-menu to protect the values set by the user.
PRESET RESERVED (Initialization reserved)
Initialization of the back-up IC is reserved. (Actually, initialization is executed the next time the power is
turned on.)
Select this sub-menu to reset to the original factory settings or to reset the back-up IC.
Any protection history will be initialized.
4 1 . P S 1 : 0 5 1 9
4 2 . P S 2 : 0 5 1 9
4 3 . D C : 0 0 3 6
R-840/NS-BP300
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-840Mcr-840Mcr-640Mcr-940