Dell SC180 Owner's Manual page 36

Expansion enclosure
Hide thumbs Also See for SC180:
Table of Contents

Advertisement

Power Supplies
Maximum inrush current Under typical line conditions and over the entire system ambient operating
Available Hard Drive Power (per Slot)
Supported hard drive
power consumption
(continuous)
IO Card Power (per Slot)
Maximum power
consumed by IO Card
Maximum available
power
Minimum available
power
Physical
Height
Width
Depth (front mounting
bracket to rear surface)
Depth (front surface to
rear surface)
Full Weight (maximum
configuration)
Weight without drives
Environmental
NOTE: For additional information about environmental measurements for specific configurations,
see dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
36
range, the inrush current may reach 55 A per power supply for 10 ms or less
Up to 1.16 A at +5 V
Up to 1.6 A at +12 V
11 W at +12 V
100 W at +12 V
1 W at +5 V (standby)
22.23 cm (8.75 inches)
48.26 cm (19 inches)
91.5 cm (36 inches)
96 cm (38 inches)
130 kg (287 lb)
62 kg (137 lb)
5° to 35°C (41° to 95°F) with a maximum temperature gradation of 10°C per
hour
NOTE: Maximum 35°C up to 2134 m (7000 ft), derate to 30°C for 2134 m
to 3000 m (7000 ft to 10,000 ft).
–40° to 70°C (–40° to 158°F) with a maximum temperature gradation of 20°C
per hour
SC180 Technical Specifications

Advertisement

Table of Contents
loading