The following configuration parameters allow you to add Waveflow devices. Up to 64 can be added.
Name / ID:
MAC Address:
If you wish to use boosters, this must be done by inputting the MAC address of the device to be
used with boosters in the "MAC address" field. For example, if we wish to use boosters 2 and 5
for the Waveflow device with MAC address 010203040506, we would insert '010203040506;2;5'
(remember that semi-colons are used for separation).
4.6.5.3- External Devices > Wavenis > Wavetherm
The following configuration parameters allow you to add Wavetherm devices. Up to 5 can be
added.
Name / ID:
MAC Address:
If you wish to use boosters, this must be done by inputting the MAC address of the device to be
used with boosters in the "MAC address" field. For example, if we wish to use boosters 2 and 5
for the Wavetherm device with MAC address 010203040506, we would insert
'010203040506;2;5' (remember that semi-colons are used for separation).
4.6.5.3- External Devices > Wavenis > Tools
In this section you will find tools to remotely access Wavenis devices at any time. Simply input the
device's MAC address (with boosters if applicable), and press the corresponding button.
Waveflow-4 Read:
with 4 entries.
Waveflow-4 Reset Alarms:
reset here.
WaveThern Read:
Generic Read RSSI:
communication concentrator (Titan router) and a remote device. If boosters are used, the RSSI
should be indicated at the end. For example, if we wish to read a Wavenis device using
boosters 3 and 5, by specifying the value '010203040506;3;5', the RSSI between booster 5
and the MAC device 010203040506 will be given.
http://www.mtxm2m.com  
 
Subject to changes without prior notice 
 
 
name to identify a Waveflow device.
Waveflow device's MAC address (hexadecimal format).
name to identify a Wavetherm device.
Wavetherm device's MAC address (hexadecimal format).
Reading of the count, alarms and battery status of a Waveflow device
If alarms are used (battery, circuit shortage, etc.) these can be
Reading of the current temperature of a Wavetherm device.
This field allows you to read the RSSI between the Wavenis
User Manual  ‐  Rel3.00.3.09 
 
 