Rs485 - Delta DX-2300 Series User Manual

Industrial ethernet cloud router
Table of Contents

Advertisement

DX - 2 3 00 Ser i es I nd us t r i al Et h er ne t C lo u d Ro ut er
_3
Slave Mode
3.4.4

RS485

RS485 (Recommended Standard - 485) is a telecommunication standard for binary serial communications between
devices. You can set up the configurations for RS485, including Baud Rate, Data Bits, Stop Bits, Parity Bits, and many
more.
3 - 2 4
Description
Parity Bits
Set up the parity bits for the serial port. Options are
None, Odd and Even.
Flow Control
Set up the flow control. Options are None, XON,
XOFF, RTS, and CTS.
MODBUS ID
Set up the ModBus ID. The value is between 1 and
247.
MODBUS Mode
Set up the communication mode for the device.
Device support ModBus RTU and ModBus ASCII.
ModBus Timeout
Set up the timeout timer from 200ms to 3000ms. If
the set value is out of range, it will be automatically
changed to its maximum or minimum value.
Default
None
None
1
ModBus RTU
200ms