DFW-V500
DFW-VL500
COMMAND SETTING AND OPERATION TIMING
One Shot CMD and actual operation timing
As shown in the following figure, it takes at least about 1 V for the actual isochronous transmission to start after the One Shot
command (CSR F0F0061Ch) has been set to the CSR of the camera.
(VDs are the reference signals inside the camera and cannot be observed from outside the camera.)
Set One Shot in this period
VD
1 V = 33.33 ms
Isochronous
If Shutter (CSR F0F0081Ch) is set to the extended exposing mode, isochronous transmission start may be delayed for the
exposure time at maximum in addition to the previous delay.
VD
SG
Isochronous
If Shutter (CSR F0F0081Ch) is set to the extended exposing mode, image data for which exposure has been started before One
Shot command is set may be output.
VD
SG
Isochronous
28
Isochronous output is prepared
Set One Shot in this period
Exposure of 4 Frames
When One Shot (Exposure Time: 4 Frames)
Set One Shot in this period
Exposure of 4 Frames
Exposure
Image Readout
Isochronous output is prepared
Exposure of 4 Frames
Image cannot be still read out
Isochronous output is prepared
Image Readout
Isochronous transmission
for only one frame starts
Image Readout