Alarm/Reference/Detail
Alarm: Qam Card <X>:
Configuration
Ref: Output <Y> Level
missing
Detail: Output Level default
to 50
Alarm: Qam Card <X>:
Configuration
Ref: Symbol Rate missing
Detail: Symbol Rate default
to <Y>
Alarm: Qam Card <X>:
Configuration
Ref: Inversion On missing
Detail: Spectrum Inv default
to NotInv
Alarm: Qam Card <X>:
Configuration
Ref: RF Output <Y> missing
Detail: RFOutput default to
On
Alarm: Qam Card <X>:
Configuration
Ref: Output <Y> <Z> Signal
missing
Detail: SignalFormat0
default to 0
Alarm: Qam Card <X>:
Configuration
Ref: Output <Y> PRBS
Stuffing missing
Detail: PRBSStuffing default
to Off
Alarm: Qam Card <X>:
Configuration
Ref: Output <Y>
ChannelMode missing
Detail:
Alarm: Qam Card <X>:
Configuration
Ref: Channel Mode Output
<Y> invalid value
Detail:
4018055 Rev B
Description
If an Output Level parameter is missing from the configuration file
then this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number and <Y> the RF output
number.
If the Symbol Rate parameter is missing from the configuration file
then this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number.
<Y>: rate depending on configuration
If the Inversion parameter is missing from the configuration file then
this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number.
If a RF Output parameter is missing from the configuration file then
this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number and <Y> the RF output
number.
If a Signal Format parameter is missing from the configuration file
then this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number, <Y> the RF Output, and <Z>
the channel (Up of Low).
If a PRBS stuffing parameter is missing from the configuration file
then this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number and <Y> the RF output
number.
If a Channel Mode parameter is missing from the configuration file
then this alarm is raised. A Scientific Atlanta representative should be
contacted.
<X> represents the QAM card number and <Y> the RF output
number.
If a Channel Mode parameter in the configuration file contains an
illegal value then this alarm is raised.
<X> represents the QAM card number and <Y> the RF Output.