Chapter 5 Viewing Alarm Messages
Alarm/Reference/Detail
Alarm: Qam Card <X>:
Calibration
Ref: Calibration file error
Detail: (see description)
Alarm: Qam Card <X>:
Oven <Y>
Ref: Oven Temperature
Detail: - - - -
Alarm: Rear Panel Fan <X>
Ref: Fan malfunction
Detail: Rear panel fan <X>
failed
56
Description
The calibration data on the QAM card in question became corrupt. A
Scientific Atlanta representative should be contacted.
<X> represents the card number. The detail will indicate the I2c error
that has been detected.
The temperature of the modulator stabilization circuit is out of
specification. The board should be left for at least 1 minute to see if the
error clears. If after 1 minute the alarm still persists then the card
should be removed and re-inserted again. If this action does not clear
the alarm then a Scientific Atlanta representative should be contacted.
This alarm clears when the communication is established with the
device.
<X> represents the QAM card position and <Y> the RF Output
number.
The indicated fan has stopped working. Check the fans. When the
fans are working again the alarm clears.
<X> represents the fan number.
4018055 Rev B